ABB MS132-10LC

Selling Points

  • 1Robust Protection: Provides short-circuit and overload protection with trip class 10 for reliable motor operation.
  • 2Adjustable Settings: Offers adjustable current settings for tailored overload protection.
  • 3Phase Loss Sensitivity: Ensures phase loss sensitivity for enhanced safety and reliability.
  • 4Manual Control: Features ON/OFF switching functionality with clear position indication for easy operation.
  • 5Durable Design: Built with mechanical durability of 100,000 cycles and electrical durability of 50,000 cycles.
Product Details
MS132-10LC
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
45 mm
Product Net Height
90 mm
Product Net Depth / Length
86.75 mm
Product Net Weight
0.265 kg
Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 50 kA (400 V AC) 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 50 kA (400 V AC) 50 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
75 A
Setting Range
6.3 ... 10 A
Rated Operational Voltage
Main Circuit 400 V AC
Rated Operational Current (Ie)
10 A
Rated Frequency (f)
Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 0.8 ... 2.0 W
Number of Poles
3P
Conventional Free-air Thermal Current (Ith)
Main Circuit 10 A
Degree of Protection
Housing IP20 Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Main Circuit 9 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1 IEC/EN 60947-2 IEC 60335-2-40 A2L
Ambient Air Temperature
Operation -25 ... +70 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations
5g 3 ... 150 Hz
Object Classification Code
F
ETIM 5
EC000074 - Motor protective circuit-breaker
ETIM 6
EC000074 - Motor protection circuit-breaker
ETIM 7
EC000074 - Motor protection circuit-breaker
ETIM 8
EC000074 - Motor protection circuit-breaker
eClass
V11.0 : 27370401
UNSPSC
39121521
IDEA Granular Category Code (IGCC)
4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Manufacturer ID
1SAM350300R1010

Specifications may be subject to change without notice