Product Model
PST60-690-70

Selling Points
- 1Advanced Motor Control: Efficiently manage motor power with precise start and stop timing.
- 2Versatile Connectivity: Supports Profibus, Modbus, DeviceNet, and CANopen for seamless integration.
- 3High Reliability: Built-in overload relay and PTC protection ensure motor safety.
- 4Easy Installation: In-line screw connection and NEMA 1/4X/12/IP10/IP20/IP66 enclosures simplify setup.
- 5Adaptable Protection: Dual motor overload protection with classes 10A, 10, 20, and 30 for comprehensive safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 160 mm | Product Net Height | 260 mm |
Product Net Depth / Length | 196 mm | Product Net Weight | 5 kg |
Rated Operational Voltage | Main Circuit 400 ... 690 V AC | Rated Control Circuit Voltage (Uc) | DC Operation 24 V |
Rated Frequency (f) | 50/60 Hz Main Circuit 50 / 60 Hz | Rated Operational Power - In-Line Connection (Pe) | (400 V) 30 kW (500 V) 37 kW (690 V) 55 kW |
Rated Operational Current - In-Line Connection (Ie) | 60 A | Rated Operational Power - Inside Delta Connection | at 400 V 55 kW at 500 V 75 kW at 690 V 90 kW |
Rated Operational Current - Inside Delta Connection | 105 A | Service Factor Percentage | 115 % |
Overload Protection | Build-in electronic overload protection | Integrated Electronic Overload | Yes |
Adjustable Rated Motor Current Ie | 30 ... 115 % | Starting Capacity at Maximum Rated Current Ie | 3xIe for 15s |
Ramp Time | 0 ... 120 second [unit of time] 1 ... 120 second [unit of time] | Initial Voltage During Start | 30 ... 70 % |
Step Down Voltage Special Ramp | 100 ... 30 % | Current Limit Function | 1.5 ... 7xIe |
Switch for Inside Delta Connection | Yes | Run Signal Relay | Yes |
By-pass Signal Relay | Yes | Fault Signal Relay | Yes |
Overload Signal Relay | Yes | Analog Outputs | 0â¦10 volts 0â¦20 mA 4â¦20 mA |
Signal Indication Ready to Start/Standby ON (LED) | Green | Signal Indication Protection (LED) | Yellow |
Signal Indication Fault (LED) | Red | Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time | 30 |
Communication | FiledBusPlug(Standard) | Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Terminal Type | Screw Terminals | Connecting Capacity Main Circuit | Rigid 1 x 10 ... 95 mm² Rigid 2 x 6 ... 35 mm² |
Connecting Capacity Control Circuit | Rigid 1 x 2.5 mm² Rigid 2 x 1.5 mm² | Connecting Capacity Supply Circuit | Rigid 1 x 2.5 mm² |
Tightening Torque | Control Circuit 0.5 N·m Main Circuit 6 N·m Supply Circuit 0.5 N·m | Product Main Type | PST60 |
Ambient Air Temperature | Operation 0 ... +50 °C Storage -25 ... +70 °C | Object Classification Code | Q |
ETIM 7 | EC000640 - Soft starter | ETIM 8 | EC000640 - Soft starter |
ETIM 9 | EC000640 - Soft starter | eClass | V11.0 : 27370907 |
UNSPSC | 39121521 | Manufacturer ID | 1SFA895006R7000 |
Specifications may be subject to change without notice