Product Model
XT2L160 LS/I R160 PMP 4P

Selling Points
- 1The XT2L160 LS/I R160 PMP 4P circuit breaker offers superior performance with a rated current of 160A and a short-circuit breaking capacity of 120kA.
- 2Designed with safety in mind, this product meets international standards like IEC60947-1 and EN60947-1, ensuring reliable operation and protection against electrical hazards.
- 3Built to last, the XT2L160 LS/I R160 PMP 4P has an electrical durability of 120 cycles per hour and a total of 8000 cycles, making it a long-lasting solution for your electrical needs.
- 4This circuit breaker complies with EU Directive 2011/65/EU and Amendment 2015/863, ensuring it meets all environmental and regulatory requirements.
- 5Suitable for various applications, including industrial and commercial settings, the XT2L160 LS/I R160 PMP 4P is a versatile and reliable choice for your electrical infrastructure.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 120.0 mm |
Product Net Height | 130 mm | Product Net Depth / Length | 82.5 mm |
Product Net Weight | 3.27 kg | Product Main Type | SACE Tmax XT |
Product Name | Moulded Case Circuit Breaker | Product Type | Automatic Circuit Breaker |
Version | P | Current Type | AC |
Electrical Durability | 8000 cycle 120 cycles per hour | Mechanical Durability | 25000 cycle 240 cycles per hour |
Number of Poles | 4P | Power Loss | at Rated Operating Conditions per Pole 13.4 W |
Rated Current (In) | 160 A | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Insulation Voltage (Ui) | 1000 V | Rated Operational Voltage | 690 V AC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA | Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA |
Rated Uninterrupted Current (Iu) | 160 A | Release | Ekip LS/I |
Release Type | EL | Remarks | ATLAS |
Short-Circuit Performance Level | L | Standards | IEC60947-2 GB/T 14028.2 |
Sub-type | XT2 | Terminal Connection Type | Plug-In Circuit-Breakers |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | Manufacturer ID | 2TFH100771R1001 |
Specifications may be subject to change without notice