Product Model

XT2L160 LS/I R160 PMP 4P

In Stock
Last updated: 2025/5/8
ABB XT2L160 LS/I R160 PMP 4P

Selling Points

  • 1The XT2L160 LS/I R160 PMP 4P circuit breaker offers superior performance with a rated current of 160A and a short-circuit breaking capacity of 120kA.
  • 2Designed with safety in mind, this product meets international standards like IEC60947-1 and EN60947-1, ensuring reliable operation and protection against electrical hazards.
  • 3Built to last, the XT2L160 LS/I R160 PMP 4P has an electrical durability of 120 cycles per hour and a total of 8000 cycles, making it a long-lasting solution for your electrical needs.
  • 4This circuit breaker complies with EU Directive 2011/65/EU and Amendment 2015/863, ensuring it meets all environmental and regulatory requirements.
  • 5Suitable for various applications, including industrial and commercial settings, the XT2L160 LS/I R160 PMP 4P is a versatile and reliable choice for your electrical infrastructure.
Product Details
XT2L160 LS/I R160 PMP 4P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Environmental Information
9AKK108467A6707
Product Net Width
120.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
3.27 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 13.4 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip LS/I
Release Type
EL
Remarks
ATLAS
Short-Circuit Performance Level
L
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Plug-In Circuit-Breakers
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100771R1001

Specifications may be subject to change without notice