Product Model
nebm-m23g15-eh- -q7n-r3leg14

Selling Points
- 1The NEBM-M23G15-EH-5-Q7N-R3LEG14 motor cable features a shielded design with 4 x 0.75 mm² and 1 x (2 x 0.75 mm²) + 1 x (2 x 0.24 mm² + 2 x 2 x 0.15 mm²) conductors, ensuring robust and reliable performance.
- 2This cable is based on the EN 61984 standard, ensuring it meets the highest quality and safety standards for industrial applications.
- 3The cable offers hybrid socket connections at the field device end and plugs and cables at the control side, providing flexibility in your automation setup.
- 4With an operational voltage range of DC 0 V...850 V and AC 0 V...630 V, and a current rating of 11.7 A at 40°C, this cable is designed to handle demanding industrial conditions.
- 5The cable has an IP67 degree of protection and operates in ambient temperatures ranging from -40°C to 90°C, making it suitable for various industrial environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Based on norm | EN 61984 | Cable designation | Without label holder |
Electrical connection 1, function | Field device end | Electrical connection 1, design | Round |
Electrical connection 1, connection type | Hybrid socket | Electrical connection 1, cable outlet | Straight |
Electrical connection 1, connection technology | M23x1 | Electrical connection 1, number of pins/wires | 15 |
Electrical connection 1, occupied pins/wires | 12 | Electrical connection 1, type of mounting | Screw-type lock |
Electrical connection for input 1, connection pattern | 00995912 | Electrical connection 2, function | Control side |
Electrical connection 2, connection type | Plugs and cables | Electrical connection 2, cable outlet | Straight |
Electrical connection 2, connection technology | RJ45 and open end | Electrical connection 2, number of pins/wires | 14 |
Electrical connection 2, occupied pins/wires | 12 | DC operating voltage range | 0V 850V |
Operating voltage range AC | 0V 630V | Current rating at 40° C | 11.7A |
Surge resistance | 6kV | Shield | yes |
Cable length | 0.5m 100m | Cable characteristic | Suitable for energy chains |
Connector cable test conditions | Test conditions on request | Bending radius, fixed cable installation | 48mm |
Bending radius, flexible cable installation | 90mm | Cable diameter | 12mm |
Cable diameter tolerance | ± 0.3 mm | Cable design | 4 x 0.75 mm2 + 1 x (2 x 0.75 mm2) + 1 x (2 x 0.24 mm2 + 2 x 2 x 0.15 mm2) |
Nominal conductor cross section | 0.24mm2 | Wire ends | Cable end sleeve |
Degree of protection | IP67 | Note on degree of protection | In mounted state |
Ambient temperature | -40°C 90°C | Ambient temperature with flexible cable installation | -25°C 80°C |
CE marking (see declaration of conformity) | As per EU low voltage directive As per EU RoHS directive | UKCA marking (see declaration of conformity) | To UK RoHS instructions To UK instructions for electrical equipment |
LABS (PWIS) conformity | VDMA24364-B2-L | Note on materials | RoHS-compliant Halogen-free |
Contamination level | 1 | Corrosion resistance class (CRC) | 1 - Low corrosion stress |
Material of cable sheath | TPE-U(PUR) | Color cable sheath | Gray |
Insulating sheath material | PP | Manufacturer ID | 5251373 |
Specifications may be subject to change without notice