Product Model

vaba-s6-1-x2-f2-cb

In Stock
Last updated: 2025/5/2
Festo vaba-s6-1-x2-f2-cb

Selling Points

  • 1Withstands severity level 2 tests according to FN 942017-4 and EN 60068-2-6.
  • 2Detects wire breaks, short circuits, and undervoltage in valves.
  • 3Features internal electronic fuse protection per valve output for safe operation.
  • 4Supports up to 12 bistable or 24 monostable valve positions.
  • 5Meets EU EMC and RoHS directives, ensuring compliance with safety standards.
Product Details
vaba-s6-1-x2-f2-cb
Festo

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Vibration resistance
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27
Valve manifold interface
Type 44, VTSA-F-CB
Diagnostics
Wire break per valve coil Short circuit of pneumatic valves Undervoltage of pneumatic valves
Max. no. of valve positions
12 for bistable pneumatic valves 24 for monostable pneumatic valves
LED indicators
1 group diagnostics
Parameterization
Fail-safe modes per channel Forcing per channel Idle mode per channel Module monitoring
Fuse protection (short circuit)
Internal electronic fuse per pneumatic valve output
DC operating voltage range
21.6V 26.4V
Intrinsic current consumption at nominal operating voltage
Typ. 110 mA for electronics with CPX-FVDA-P2 Typ. 25 mA for pneumatic valves without CPX-FVDA-P2 Typ. 45 mA for electronics without CPX-FVDA-P2 Typ. 90 mA for pneumatic valves with CPX-FVDA-P2
Max. power supply per channel
0.2?A
Max. residual current per module
4.5A
Nominal operating voltage DC
24V
Electrical isolation between channel and internal bus
Yes, when using an additional supply for the pneumatic valves
CE marking (see declaration of conformity)
As per EU EMC directive As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC To UK RoHS instructions
Corrosion resistance class (CRC)
0 - No corrosion stress
LABS (PWIS) conformity
VDMA24364-B1/B2-L
Storage temperature
-20°C 60°C
Degree of protection
IP65
Ambient temperature
-5°C 50°C
Product weight
754g
Electrical actuation
Fieldbus
Electrical connection output, function
Safe digital output
Electrical connection output, connection type
Socket
Electrical connection output, connection technology
M12x1 A-coded as per EN 61076-2-101
Electrical output connection, number of pins/wires
5
Electrical connection
Via CPX
Note on materials
RoHS-compliant
Material of sub-base
Die-cast aluminum
Cover material
PA
Seals material
NBR
Material of screws
Steel
Manufacturer ID
8068241

Specifications may be subject to change without notice