Product Model
FL IF 2FX SM SC-D

Selling Points
- 1Robust Ethernet transmission even in medium-range environments prone to interference.
- 2Supports 100Base-FX single mode glass fibers with a wavelength of 1300 nm.
- 3SC connection direction downward for reliable connectivity.
- 4Dimensions: 31 mm width, 85 mm height, and 72.5 mm depth.
- 5Compliant with EMC directives and UL 94 V0 flammability rating.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Note on application | Only for industrial use | Product type | Extension module |
Type | fine granularity | Article revision | 09 |
Basic functions | Media module for modular managed switch | Electrical isolation | 100Base-FX // supply |
Local diagnostics | LEDs at head station / extension module | Maximum power dissipation for nominal condition | 21.6 W |
Test voltage | 2 kV AC | Transmission medium | Copper
FO |
Supply voltage | via head station | Power supply connection | from FL SWITCH GHS or FXT |
Typical current consumption | 200 mA | Connection method | SC |
Transmission speed | 100 Mbps | Transmission length | 36000 m (maximum (depends on the fiber used)) |
No. of channels | 2 | Connection method | SC |
Transmission speed | 100 Mbps | Transmission length | 36000 m (fiberglass with F-G 9/125 0.36 dB/km)
32000 m (fiberglass with F-G 9/125 0.4 dB/km)
26000 m (fiberglass with F-G 9/125 0.5 dB/km) |
Wavelength | 1300 nm | No. of channels | 2 (SC single mode) |
Width | 31 mm | Height | 85 mm |
Depth | 72.5 mm | Color | green |
Flammability rating according to UL 94 | V0 | Housing material | PA |
Degree of protection | IP20 | Ambient temperature (operation) | 0 °C ... 55 °C (non-condensing) |
Ambient temperature (storage/transport) | -20 °C ... 70 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC | Conformance with EMC directives | IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B
IEC 61000-4-3 (immunity to radiated interference) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion A
IEC 61000-4-6 (immunity to conducted interference) Criterion A
IEC 61000-4-8 (immunity to magnetic fields) Criterion A
EN 55022 (emitted interference) Criterion A |
Noise immunity | EN 61000-6-2:2005 | Noise emission | EN 61000-6-3/-4 |
Free from substances that could impair the application of coating | In acc. with VW specification | Electrical isolation | 100Base-FX // supply |
Mounting type | In the host system |
Specifications may be subject to change without notice