Product Model

FLK 50/EZ-DR/VIP/ 200/SO233

In Stock
Last updated: 2025/5/1
Phoenix Contact FLK 50/EZ-DR/VIP/ 200/SO233

Selling Points

  • 1High-Performance Connectors: Equipped with 50-position connectors for reliable and efficient data transfer.
  • 2Versatile Compatibility: Compatible with a wide range of industrial controllers, including SIEMENS, ALLEN-BRADLEY, and HONEYWELL.
  • 3Durable Construction: Constructed with tin-plated copper litz wires and PVC insulation for long-lasting performance.
  • 4Flexible Installation: Suitable for both fixed and flexible installations, with operating temperatures ranging from -10°C to 70°C.
  • 5Comprehensive Certifications: Meets rigorous standards with certifications including UL, GOST, and IEC 60332-1 for flame resistance and oil resistance.
Product Details
FLK 50/EZ-DR/VIP/ 200/SO233
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
System cable
Ambient temperature (operation)
-20 °C ... 50 °C
Ambient temperature (storage/transport)
-20 °C ... 70 °C
Operating voltage (AC/DC)
≤ 48 V AC/DC
Current (Per path)
≤ 1 A
Cable length
2 m
UL AWM Style
2464/1061
Number of positions
50
Shielded
no
Cable type
50X0.14 [PVC]
Conductor type
Round cable set
Conductor structure signal line
7x 0.16 mm
AWG signal line
26
Conductor cross section
50x 0.14 mm²
Wire diameter incl. insulation
1 mm ±0.03 mm
External cable diameter
10.30 mm ±0.4 mm
Outer sheath, material
Semi-rigid PVC
External sheath, color
gray
Conductor material
Tin-plated Cu litz wires
Cable resistance
≤ 145 Ω/km (20 °C)
Insulation resistance
≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation
86 mm
Smallest bending radius, movable installation
161 mm
Dynamic load capacity (bending)
Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter)
Halogen-free
no
Flame resistance
IEC 60332-1-2 (raw cable) VDE 0842, Part 332-1-2 (raw cable) IEC 60332-3-22 (raw cable) UL VW-1 CSA FT-1
Resistance to oil
can withstand occasional splashes (raw cable)
Connection method
IDC/FLK socket strip
Number of connections
1
Number of positions
50
Pitch
2.54 mm
Connection method
IDC/FLK socket strip
Number of connections
1
Number of positions
50
Pitch
2.54 mm
Notes on operation
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Specifications may be subject to change without notice