Product Model

FL MC EF 660 SCRJ

In Stock
Last updated: 2025/6/16
Phoenix Contact FL MC EF 660 SCRJ

Selling Points

  • 1Converts 100Base-T(X) Ethernet to polymer or HCS (PCF) optical fibers.
  • 2Supports SC-RJ standard for Profinet, ensuring compatibility with industrial networks.
  • 3Offers extended temperature range from -40°C to +60°C, suitable for harsh environments.
  • 4Includes auto-MDI/MDIX switching and Link-Fault-Pass-Through (LFP) for reliable operation.
  • 5Features integrated diagnostic LEDs for easy monitoring of link and activity status.
Product Details
FL MC EF 660 SCRJ
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Note on application
Only for industrial use
Product type
Media converter
MTTF
929 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) 461 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) 204 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Electrical isolation
VCC // Ethernet
Maximum power dissipation for nominal condition
2.4 W
Test voltage data interface/power supply
1.5 kV 1500 V
Supply voltage range
18 V DC ... 32 V DC (via pluggable COMBICON screw terminal block) 18 V DC ... 32 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption
≤ 85 mA (24 V DC)
Max. current consumption
100 mA (24 V DC)
Protective circuit
Reverse polarity protection
Output name
Relay output
Number of outputs
2
Contact switching type
N/O contact
Maximum switching voltage
60 V AC/DC
Max. switching current
1 A
Connection method
Plug-in screw terminal block (COMBICON), redundancy possible
Tightening torque
0.56 Nm ... 0.79 Nm
Signal
Ethernet PROFINET
Transmit capacity, minimum
min. -8 dBm (980/1000 µm, static) min. -19 dBm (200/230 µm, static)
Transmit capacity, maximum
max. -2 dBm (980/1000 µm, static) max. -11 dBm (200/230 µm, static)
Transmission length incl. 3 dB system reserve
50 m (Polymer fiber with F-P 980/1000 230 dB/km) 100 m (PCF fiber with F-K 200/230 8 dB/km)
Connection method
SC-RJ
Wavelength
660 nm
Minimum receiver sensitivity
-23 dBm (980/1000 µm, static) -26.8 dBm (200/230 µm, static)
Transmission medium
Polymer fiber PCF fiber
Transmission speed
100 Mbps
Connection method
RJ45 jack, shielded
No. of channels
1
Transmission length
100 m (shielded twisted pair)
Transmission medium
Copper
Link through
Link fault pass through
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
Color (Housing)
green (RAL 6021)
Material (Housing)
PA V0
Fiber types
980/1000 µm 200/230 µm Polymer fiber PCF fiber
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Altitude
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Certificate
CE-compliant
Identification
ISA-S71.04-1985 G3 Harsh Group A
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Conducted noise emission
EN 61000-6-3 Class B, domain of use: residential and small commercial
Standards/regulations
EN 61000-4-2
Contact discharge
± 6 kV (Test Level 3)
Discharge in air
± 8 kV (Test Level 3)
Indirect discharge
± 6 kV
Comments
Criterion B
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 3 GHz (Test Level 3)
Field intensity
10 V/m
Comments
Criterion A
Standards/regulations
EN 61000-4-4
Input
± 2.2 kV (1 minute)
Signal
± 2.2 kV (1 minute)
Comments
Criterion B
Standards/regulations
EN 61000-4-5
Input
± 0.5 kV (Supply)
Signal
± 1 kV (Shielded cable)
Comments
Criterion B
Standards/regulations
EN 61000-4-6
Frequency range
0.15 MHz ... 80 MHz
Comments
Criterion A
Voltage
10 V
Standards/regulations
EN 61000-6-4
Comments
Class A, industrial applications
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected by the device itself.
Free from substances that could impair the application of coating
VDMA 24364:2018-05
Mounting type
DIN rail mounting

Specifications may be subject to change without notice