Product Model

IB IL 24 DO 2

In Stock
Last updated: 2025/5/3
Phoenix Contact IB IL 24 DO 2

Selling Points

  • 1Output Digital Signals Efficiently: Designed for use within Inline stations, this terminal outputs digital signals effectively.
  • 22 Digital Outputs: Equipped with two digital outputs for versatile connectivity.
  • 3High Current Capacity: Each output supports up to 2A of current, ensuring reliable operation.
  • 4Short-Circuit Protection: Built-in short-circuit protection for added safety and reliability.
  • 5Compact Design: Measures 12.2 mm x 120 mm x 71.5 mm, making it ideal for space-constrained applications.
Product Details
IB IL 24 DO 2
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Type
modular
No. of channels
2
Diagnostics messages
Short-circuit or overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module
ID code (dec.)
189
ID code (hex)
BD
Length code (hex)
C2
Length code (dec)
194
Process data channel
2 bit
Input address area
0 Byte
Output address area
2 bit
Register length
2 bit
Required parameter data
3 Byte
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
max. 33 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 1 A
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)
500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (I/O) / functional ground
500 V AC, 50 Hz, 1 min
Output name
Digital outputs
Connection method
Spring-cage connection
Connection technology
2-, 3-, 4-conductor
Number of outputs
2
Protective circuit
Overload protection, short-circuit protection of outputs
Output voltage
24 V DC (U
Maximum output current per channel
500 mA
Maximum output current per module
1 A
Nominal output voltage
24 V DC (voltage difference at I
Nominal load, inductive
12 W
Nominal load, lamp
12 W
Nominal load, ohmic
12 VA
Behavior with overload
Auto restart
Behavior with inductive overload
Output can be destroyed
Behavior at voltage switch-off
The output follows the power supply without delay
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection method
Inline data jumper
Diagnostics
Short-circuit or overload of the digital outputs
Message
Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module
Width
12.2 mm
Height
119.8 mm
Depth
71.5 mm
Note on dimensions
Housing dimensions
Color
green
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting