Product Model
IB IL AO 1/SF-XC-PAC

Selling Points
- 1High Precision: 16-bit resolution for precise analog signal management.
- 2DIN Rail Mounting: Easy installation on DIN rails for efficient system integration.
- 3Transient Protection: Robust transient protection of outputs for reliable operation.
- 4Wide Operating Range: Operates from -25°C to +55°C, ensuring durability in various environments.
- 5Compact Design: Dimensions of 136.8 x 12.2 x 71.5 mm for space-efficient installations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 24.4 mm | Height | 135 mm |
Depth | 71.5 mm | Note on dimensions | Housing dimensions |
Note on application | Only for industrial use | Number of interfaces | 2 |
Connection method | Inline data jumper | Transmission speed | 500 kbps |
ID code (dec.) | 125 | ID code (hex) | 7D |
Length code (hex) | 01 | Length code (dec) | 01 |
Process data channel | 16 bit | Input address area | 0 Byte |
Output address area | 2 Byte | Register length | 16 bit |
Required parameter data | 4 Byte | Required configuration data | 4 Byte |
Output name | Analog output | Connection technology | 2-conductor |
Note regarding the connection technology | shielded | Number of outputs | 1 |
D/A converter resolution | 16 bit | Protective circuit | Transient protection of outputs |
Representation of output values | 16-bit straight binary | DAC resolution | 16 bit |
Process data update | < 1 ms | Current output signal | 0 mA ... 20 mA
4 mA ... 20 mA |
Load/output load current output | < 500 Ω | Voltage output signal | 0 V ... 10 V |
Load/output load voltage output | > 2 kΩ | Product type | I/O component |
Product family | Inline | Type | modular |
Scope of delivery | including Inline connectors and marking fields | Operating mode | Process data mode with one word |
Special properties | Extreme conditions version | Diagnostics messages | Failure of or insufficient communications power U |
Article revision | 02 | Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 40 mA
typ. 30 mA | Supply voltage | 24 V DC (via voltage jumper) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | max. 65 mA
typ. 50 mA |
Test voltage: 7.5 V supply (bus logic), 24 V supply U | 500 V AC, 50 Hz, 1 min | Test voltage: 7.5 V supply (bus logic), 24 V supply U | 500 V AC, 50 Hz, 1 min |
Test voltage: I/O/functional ground | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) | Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice