Product Model
IB IL TEMP 4/8 RTD-PAC/CN

Selling Points
- 18-channel analog input module for resistive temperature sensors.
- 2Supports platinum and nickel sensors according to DIN and SAMA directives.
- 316-bit resolution for precise temperature measurement.
- 4DIN rail mounting for easy installation in industrial environments.
- 5Robust design with IP20 protection, ideal for harsh industrial conditions.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Color | green | Connection method | Inline data jumper |
Transmission speed | 500 kbps | Transmission physics | Copper |
ID code (dec.) | 223 | ID code (hex) | DF |
Length code (hex) | 05 | Length code (dec) | 05 |
Process data channel | 80 bit | Input address area | 10 Byte |
Output address area | 10 Byte | Register length | 96 bit |
Required parameter data | 31 Byte | Required configuration data | 5 Byte |
Input name | Analog RTD inputs | Description of the input | Input for resistive temperature sensors |
Number of inputs | 8 | Connection method | Spring-cage connection |
Connection technology | 2, 3-conductor | A/D conversion time | max. 10 µs |
Sensor types (RTD) that can be used | Pt, Ni, KTY, Cu sensors, linear resistors | Data formats | IB IL, IB ST, S7 compatible |
Measuring principle | Successive approximation | Measured value representation | 16 bits (15 bits + sign bit) |
Linear resistance measuring range | 0 Ω ... 400 Ω
0 Ω ... 20 kΩ | Process data update | 6 ms (Up to 230 ms possible depending on operating mode) |
Product type | I/O component | Type | modular
Inline |
Operating mode | Process data mode with 5 words/1 word PCP | Power consumption | typ. 1.24 W |
Supply voltage | 7.5 V DC (via voltage jumper) | Current draw | typ. 75 mA |
Supply voltage | 24 V DC (via voltage jumper) | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | typ. 28 mA | Test voltage: 7.5 V supply (bus logic)/±15.5 V, ±5 V analog supply (analog I/O) | 500 V AC, 50 Hz, 1 min |
Test voltage: 7.5 V supply (bus logic)/functional ground | 500 V AC, 50 Hz, 1 min | Test voltage: ±15.5 V, ±5 V analog supply (analog I/O)/functional ground | 500 V AC, 50 Hz, 1 min |
Connection name | Inline connector | Connection method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Ambient temperature (operation) | -25 °C ... 55 °C |
Degree of protection | IP20 | Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) | Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) | Mounting type | DIN rail mounting |
Specifications may be subject to change without notice