Product Model

PLC-OSP- 60DC/300DC/ 1

In Stock
Last updated: 2025/5/1
Phoenix Contact PLC-OSP- 60DC/300DC/  1

Selling Points

  • 1Highly Reliable Switching: Wear-free switching with no contact bounce ensures consistent performance.
  • 2Versatile Input Range: Operates with an input voltage range of 48 V DC to 72 V DC.
  • 3Integrated Protection: Features reverse polarity protection, polarity protection diode, and surge protection.
  • 4Fast Response Time: Typical response time is 0.3 ms for quick and reliable switching.
  • 5Durable Design: Resistant to vibrations and shocks, making it suitable for harsh industrial environments.
Product Details
PLC-OSP- 60DC/300DC/ 1
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Solid-state relay module
Product family
PLC-INTERFACE
Application
With integrated solid-state relay
Operating mode
100% operating factor
Date of last data management
27.05.2024
Insulation
Basic insulation
Overvoltage category
III
Pollution degree
2
Rated insulation voltage
300 V
Rated surge voltage
2.5 kV
Nominal input voltage U
60 V DC
Input voltage range in reference to U
0.8 ... 1.2
Input voltage range
48 V DC ... 72 V DC
Switching threshold "0" signal in reference to U
≤ 0.4
Switching threshold "1" signal in reference to U
≥ 0.8
Typical input current at U
5 mA
Typical response time
0.3 ms
Typical turn-off time
0.7 ms
Operating voltage display
Yellow LED
Protective circuit
Reverse polarity protection; Polarity protection diode Surge protection; Varistor
Transmission frequency
50 Hz
Designation
Output data
Contact switching type
1 N/O contact
Design of digital output
electronic
Output voltage range
12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Limiting continuous current
1 A (see derating curve)
Voltage drop at max. limiting continuous current
< 500 mV
Protective circuit
Reverse polarity protection; Polarity protection diode Surge protection; Varistor
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 14
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 14
Width
6.2 mm
Height
80 mm
Depth
86 mm
Color
green (RAL 6021)
Flammability rating according to UL 94
V0 (Housing)
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Standards/regulations
IEC 60664 EN 50178
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice