Product Model
PLC-RPT-230UC/21-21/SO46

Selling Points
- 1Efficient Interference Protection: Prevents interference currents and voltages on the control side.
- 2Durable Design: Mechanical service life of approx. 3x 107 cycles ensures long-term reliability.
- 3Versatile Connectivity: Push-in connection method for easy and secure wiring.
- 4High Switching Capacity: Handles up to 6 A continuous current and 15 A inrush current.
- 5Compliant with Standards: Meets IEC 60947-5-1 and CE-compliant for safe operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Notes on operation | The PLC-ATP partition plate must be installed for voltages greater than 250 V (L1, L2, L3) between identical terminal blocks on adjacent modules. | Notes on operation | The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
Notes on operation | The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. | Assembly note | The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. |
Product type | Relay Module | Product family | PLC-INTERFACE |
Application | Filter to prevent interference | Operating mode | 100% operating factor |
Mechanical service life | approx. 3x 10 | Date of last data management | 08.07.2024 |
Article revision | 03 | Insulation | Basic insulation |
Overvoltage category | III | Pollution degree | 3 |
Maximum power dissipation for nominal condition | 2.3 W | Test voltage (Winding/contact) | 4 kV |
Rated insulation voltage | 250 V AC | Rated surge voltage | 4 kV (Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths) |
Nominal input voltage U | 230 V AC
220 V DC | Input voltage range | 179.4 V AC ... 264.5 V AC (20 °C)
171.6 V DC ... 253 V DC (20 °C) |
Nominal voltage (plugged-in electromechanical relay) | 110 V DC | Mains frequency | 50/60 Hz |
Drive and function | monostable | Drive (polarity) | polarized |
Typical input current at U | 8.5 mA (50 Hz)
10 mA (60 Hz) | Typical response time | 7 ms |
Typical release time | 10 ms | Typical release voltage | 60 V AC |
Protective circuit | RC element
Bridge rectifier | Status display | LED (yellow) |
Contact switching type | 2 changeover contacts | Type of switch contact | Single contact |
Contact material | AgNi | Maximum switching voltage | 250 V AC/DC |
Minimum switching voltage | 5 V (10 mA) | Limiting continuous current | 6 A |
Maximum inrush current | 15 A (300 ms) | Min. switching current | 10 mA (5 V) |
Interrupting rating (ohmic load) max. | 144 W (24 V DC)
96 W (48 V DC)
60 W (60 V DC)
44 W (110 V DC)
57 W (220 V DC)
1500 VA (250 V AC) | Switching capacity min. | 0.12 W |
Switching capacity | 2 A (DC13, 24 V)
0.2 A (DC13, 250 V)
3 A (AC15, 24 V)
3 A (AC15, 250 V) | Connection method | Push-in connection |
Stripping length | 10 mm | Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule) | Conductor cross section AWG | 26 ... 14 |
Width | 14 mm | Height | 80 mm |
Depth | 94 mm | Color | gray (RAL 7042) |
Degree of protection (Relay base) | IP20 (Relay base) | Degree of protection (Relay) | RT III (Relay) |
Degree of protection (Installation location) | IP54 (Installation location) | Ambient temperature (operation) | -40 °C ... 55 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C | Altitude | ≤ 2000 m |
Certificate | CE-compliant | Certificate | UKCA-compliant |
Certificate | TAE0000196 | Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 |
Temperature | D | Humidity | A |
Vibration | B/C | EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board | Electromagnetic compatibility | Conformance with EMC directive |
Low Voltage Directive | Conformance with Low Voltage Directive | Standards/regulations | IEC 60947-5-1 |
Mounting type | DIN rail mounting | Assembly note | in rows with zero spacing |
Mounting position | any |