Product Model
PLC-RSP- 60DC/21AU

Selling Points
- 1Universal Application: Suitable for various industrial applications.
- 2100% Operating Factor: Ensures continuous operation without downtime.
- 3High Switching Capacity: Handles up to 250 V AC/DC with a switching capacity of 2 A at 24 V DC.
- 4Efficient Connection: Utilizes V8 adapter for seamless system cabling integration.
- 5Reliable Design: Features RT III sealed relay and multi-layer gold contact for safe isolation and long service life.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
EMC note | EMC: class A product, see manufacturer's declaration in the download area | Product type | Relay Module |
Product family | PLC-INTERFACE | Application | Universal |
Operating mode | 100% operating factor | Mechanical service life | 2x 10 |
Date of last data management | 10.10.2023 | Overvoltage category | III |
Pollution degree | 3 | Maximum power dissipation for nominal condition | 0.29 W |
Test voltage (Winding/contact) | 4 kV AC (50 Hz, 1 min., winding/contact) | Nominal input voltage U | 60 V DC |
Input voltage range | 46.6 V DC ... 84 V DC | Typical input current at U | 4.8 mA |
Typical response time | 5 ms | Typical release time | 8 ms |
Protective circuit | Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode | Operating voltage display | Yellow LED |
Contact switching type | 1 changeover contact | Type of switch contact | Single contact |
Contact material | AgSnO, hard gold-plated | Maximum switching voltage | 30 V AC
36 V DC |
Minimum switching voltage | 100 mV (at 10 mA) | Limiting continuous current | 50 mA |
Maximum inrush current | 50 mA | Min. switching current | 1 mA (at 24 V) |
Interrupting rating (ohmic load) max. | 1.2 W (at 24 V DC) | Note | — |
Maximum switching voltage | 250 V AC/DC | Minimum switching voltage | 5 V (at 100 mA) |
Limiting continuous current | 6 A | Min. switching current | 10 mA (at 12 V) |
Interrupting rating (ohmic load) max. | 140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC) | Switching capacity | 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15) |
Connection method | Spring-cage connection | Stripping length | 8 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² | Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 14 | Connection method | Spring-cage connection |
Stripping length | 8 mm | Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² | Conductor cross section AWG | 26 ... 14 |
Width | 6.2 mm | Height | 80 mm |
Depth | 94 mm | Color | green (RAL 6021) |
Flammability rating according to UL 94 | V0 (Housing) | Degree of protection (Relay base) | IP20 (Relay base) |
Ambient temperature (operation) | -40 °C ... 60 °C | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Standards/regulations | IEC 60664
IEC 60947-5-1 | Assembly note | in rows with zero spacing |
Mounting position | any |
Specifications may be subject to change without notice