Product Model

QUINT-PS-100-240AC/24DC/10/EX

In Stock
Last updated: 2025/5/3
Phoenix Contact QUINT-PS-100-240AC/24DC/10/EX

Selling Points

  • 1Operates from 100 V AC to 240 V AC, ensuring compatibility with various power sources.
  • 2Exceeds 91% efficiency, minimizing energy loss and maximizing performance.
  • 3Equipped with transient surge protection, varistor, and gas-filled surge arrester for reliable operation.
  • 4Handles high inrush currents with POWER BOOST, ensuring reliable starting of heavy loads.
  • 5Built with AluNox (AlMg1) housing material, providing a robust and long-lasting design.
Product Details
QUINT-PS-100-240AC/24DC/10/EX
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Nominal input voltage range
100 V AC ... 240 V AC
Input voltage range
85 V AC ... 264 V AC 90 V DC ... 250 V DC
Input voltage range AC
85 V AC ... 264 V AC
Input voltage range DC
90 V DC ... 250 V DC
Voltage type of supply voltage
AC/DC
Inrush current
< 15 A (typical)
Inrush current integral (I
1.5 A
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Mains buffering time
> 40 ms (120 V AC) > 40 ms (230 V AC)
Current consumption
approx. 2.4 A (120 V AC) 1.3 A (230 V AC)
Nominal power consumption
264 W
Typical response time
< 1 s
Input fuse
6.3 A (slow-blow, internal)
Permissible DC backup fuse
DC: Connect a suitable fuse upstream
Recommended breaker for input protection
10 A ... 16 A (Characteristics B, C, D, K)
Efficiency
> 88 %
Nominal output voltage
24 V DC ±1 %
Setting range of the output voltage (U
22.5 V DC ... 28.5 V DC
Nominal output current (I
10 A (up to 60 °C)
POWER BOOST (I
15 A
Derating
60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance
35 V DC
Protection against overvoltage at the output (OVP)
≤ 35 V DC
Residual ripple
< 100 mV
Output power
240 W
Maximum no-load power dissipation
4 W
Power loss nominal load max.
33 W
Connection in parallel
yes, for redundancy and increased capacity
Connection in series
yes
Output description
U
Maximum switching voltage
≤ 24 V
Output voltage
+ 24 V DC (Signal)
Maximum inrush current
max. 44 mA
Continuous load current
≤ 40 mA
Output description
Relay contact, U
Maximum switching voltage
≤ 30 V AC/DC
Maximum inrush current
≤ 1 A
Continuous load current
≤ 1 A
Connection method
Pluggable screw connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
7 mm
Screw thread
M3
Connection method
Pluggable screw connection
Conductor cross section, rigid min.
0.5 mm²
Conductor cross section, rigid max.
16 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Stripping length
7 mm
Screw thread
M4
Conductor cross section, rigid min.
0.5 mm²
Conductor cross section, rigid max.
16 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Screw thread
M4
Types of signaling
LED Active switching output Relay contact
Operating voltage display
Green LED
Status display
"DC OK" LED green
Note on status display
U
Status display
"DC OK" LED green
Number of phases
1.00
Insulation voltage input/output
4 kV AC (routine test) 2 kV AC (type test)
Product type
Power supply
Product family
QUINT POWER
MTBF (IEC 61709, SN 29500)
> 500000 h
Article revision
22
Protection class
I
Width
85 mm
Height
130 mm
Depth
125 mm
Width
122 mm
Height
130 mm
Depth
88 mm
Assembly note
alignable: horizontally 0 mm, vertically 50 mm
Mounting position
horizontal DIN rail NS 35, EN 60715
Housing material
Metal
Type of housing
AluNox (AlMg1)
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
100 % (condensation permitted)
Declaration of conformity in acc. with EN 60079-15
 II 3 G Ex nAC IIC T4 X
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currents
EN 61000-3-2
Standard - Electrical safety
EN 60950-1/VDE 0805 (SELV) EN 61558-2-17
Standard - Equipment safety
GS (tested safety)
Standard - Safe isolation
DIN VDE 0100-410
Standard - Safety of transformers
EN 61558-2-17
Standards/specifications
EN 60079-0
Shipbuilding approval
DNV GL (EMC A)
UL approvals
UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950-1 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
ATEX
 II 3 G Ex nA nC IIC T4 Gc X
Electromagnetic compatibility
Conformance with EMC directive 89/336/EC
EMC requirements for noise immunity
EN 61000-6-2
Noise emission
EN 55011 (EN 55022)

Specifications may be subject to change without notice