Product Model
RIF-1-RSC-LDP-24DC/2X21/FG

Selling Points
- 1High-Quality Industrial Control: Designed for industrial control equipment, ensuring reliability and precision.
- 224V DC Input: Compatible with 24V DC power, ideal for various industrial applications.
- 3Forcedly Guided Contacts: Meets DIN EN 50205 standards, ensuring safe and reliable switching.
- 4Durable Construction: Built with AgNi contacts, offering high switching voltage and current capacity.
- 5Easy Installation: Pre-assembled with screw connection, simplifying integration into your system.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Relay Module | Product family | RIFLINE complete |
Application | Forcibly guided contacts | Operating mode | 100% operating factor |
Mechanical service life | approx. 10 | B | 600000 Cycles (AC1; 250 V / 6 A; 1 NO)
900000 Cycles (AC1; 250 V / 3 A; 1 NO)
1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO)
300000 Cycles (DC13; 24 V / 3 A; 1 NO)
1000000 Cycles (DC13; 24 V / 1,5 A; 1 NO)
3000000 Cycles (DC13; 24 V / 0,75 A; 1 NO) |
Date of last data management | 21.08.2024 | Article revision | 03 |
Insulation | Safe isolation between input and output
Basic insulation between the changeover contacts | Overvoltage category | III |
Pollution degree | 2 | Maximum power dissipation for nominal condition | 0.72 W |
Test voltage (Winding/contact) | 4 kV | Test voltage () | 1.5 kV |
Test voltage (Changeover contact/changeover contact) | 2.5 kV | Rated insulation voltage | 250 V AC (Input/output) |
Rated surge voltage | 6 kV (Input/output)
4 kV (between the changeover contacts) | Current | 10 A (RT28-32) |
Voltage | 500 V (SCPD) | Short-circuit current | 1 kA (conditional short-circuit current) |
Nominal operating voltage U | 24 V DC | Input voltage range | 20.4 V DC ... 28.8 V DC (20 °C) |
Input voltage range in reference to U | see diagram | Drive and function | monostable |
Drive (polarity) | polarized | Typical input current at U | 30 mA |
Typical response time | 15 ms | Typical release time | 10 ms |
Coil voltage | 24 V DC | Protective circuit | Freewheeling diode |
Operating voltage display | Yellow LED | Contact switching type | 2 changeover contacts, forcibly actuated |
Type of switch contact | Single contact | Contact material | AgSnO |
Maximum switching voltage | 250 V AC/DC | Limiting continuous current | 6 A |
Interrupting rating (ohmic load) max. | 144 W (24 V DC)
58 W (48 V DC)
54 W (60 V DC)
55 W (110 V DC)
55 W (220 V DC)
1500 VA (250 V AC) | Utilization category CB Scheme (IEC 60947-5-1) | AC15, 3 A/240 V (N/O contact) |
Connection method | Screw connection | Stripping length | 8 mm |
Conductor cross section rigid | 0.5 mm² ... 4 mm² | Conductor cross-section rigid (2 conductors with same cross section) | 0.5 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.5 mm² ... 4 mm²
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve) | Conductor cross section flexible (2 conductors with same cross section) | 0.5 mm² ... 2.5 mm²
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve) |
Conductor cross section AWG | 20 ... 10 (solid)
20 ... 12 (flexible) | Tightening torque | 0.5 Nm ... 0.6 Nm |
Width | 16 mm | Height | 90 mm |
Depth | 75 mm | Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V2 (Housing) | Degree of protection (Relay base) | IP20 (Relay base) |
Degree of protection (Relay) | RT I (Relay) | Ambient temperature (operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Altitude | ≤ 2000 m |
Certificate | CE-compliant | Certificate | UKCA-compliant |
Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 | Standards/regulations | IEC 60947-5-1
IEC 61810-3 |
Standards/regulations | DIN EN 60947-5-1 | Mounting type | DIN rail mounting |
Assembly note | in rows with zero spacing | Mounting position | any |
Specifications may be subject to change without notice