Product Model
UT 4-HESI (5X20)

Selling Points
- 1High Current Rating: 6.3A nominal current for reliable power distribution.
- 2Fused Design: Ensures safe operation with a glass fuse type G / 5 x 20.
- 3Durable Construction: Made in Germany with a robust blue color finish.
- 4Easy Installation: Screw termination method for quick and secure connections.
- 5Versatile Use: Suitable for various industrial applications with a maximum voltage rating of 500V.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Fuse terminal block | Area of application | Railway industry
Machine building
Plant engineering |
Number of connections | 2 | Number of rows | 1 |
Potentials | 1 | Article revision | 14 |
Overvoltage category | III | Degree of pollution | 3 |
Fuse type | Glass / ceramics / ... | Rated surge voltage | 6 kV |
Maximum power dissipation for nominal condition | 1.02 W | Fuse | G / 5 x 20 |
Maximum power dissipation | max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) | Number of connections per level | 2 |
Nominal cross section | 4 mm² | Screw thread | M3 |
Tightening torque | 0.6 ... 0.8 Nm | Stripping length | 9 mm |
Internal cylindrical gage | A4 | Connection in acc. with standard | IEC 60947-7-3 |
Conductor cross section rigid | 0.14 mm² ... 6 mm² | Cross section AWG | 26 ... 10 (converted acc. to IEC) |
Conductor cross section flexible | 0.14 mm² ... 6 mm² | Conductor cross section, flexible [AWG] | 26 ... 10 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 4 mm² | Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 4 mm² |
2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² | 2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.14 mm² ... 1.5 mm² | 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1.5 mm² |
Nominal current | 6.3 A | Maximum load current | 6.3 A (the current is determined by the fuse used) |
Nominal voltage | 500 V (The voltage is determined by the fuse or selected LED display) | Nominal cross section | 4 mm² |
Width | 6.2 mm | Height | 57.8 mm |
Depth on NS 35/7,5 | 75.6 mm | Depth on NS 35/15 | 83.1 mm |
Color | black (RAL 9005) | Flammability rating according to UL 94 | V0 |
Insulating material group | I | Insulating material | PA |
Static insulating material application in cold | -60 °C | Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
Surface flammability NFPA 130 (ASTM E 162) | passed | Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed | Test voltage setpoint | 7.3 kV |
Result | Test passed | Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Result | Test passed | Result | Test passed |
Test voltage setpoint | 1.89 kV | Result | Test passed |
Open side panel | No | Result | Test passed |
Result | Test passed | Rotation speed | 10 (+/- 2) rpm |
Revolutions | 135 | Conductor cross section/weight | 0.14 mm² / 0.2 kg
4 mm² / 0.9 kg
6 mm² / 1.4 kg |
Result | Test passed | Time of exposure | 30 s |
Result | Test passed | Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
Spectrum | Service life test category 1, class B, body mounted | Frequency | f |
ASD level | 1.857 (m/s²)²/Hz | Acceleration | 0.8g |
Test duration per axis | 5 h | Test directions | X-, Y- and Z-axis |
Result | Test passed | Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
Pulse shape | Semi-sinusoidal | Acceleration | 5g |
Shock duration | 30 ms | Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) | Result | Test passed |
Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) | Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Ambient temperature (assembly) | -5 °C ... 70 °C | Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % | Permissible humidity (storage/transport) | 30 % ... 70 % |
Connection in acc. with standard | IEC 60947-7-3 | Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice