Selling Points

  • 11. High Performance and Reliability: The Allen-Bradley 140G-G3C3-C50-KJ-MB is engineered to withstand rigorous industrial conditions, ensuring long-term performance and minimal downtime.;
  • 22. Thermal-Magnetic Protection: Equipped with thermal-magnetic protection, this circuit breaker offers comprehensive protection against overloads and short circuits, ensuring the safety of your equipment and personnel.;
  • 33. High Interrupting Rating: With a 65kA interrupting rating, the 140G-G3C3-C50-KJ-MB can handle high short-circuit currents, making it suitable for demanding industrial applications.;
  • 44. IP40 Protection: The IP40 rating provides excellent protection against solid particles and dust, ensuring the breaker operates reliably in harsh environments.;
  • 55. Versatile Mounting Options: This circuit breaker offers standard busbar mount and bottom front terminal options, providing flexibility in installation and integration into your existing systems.
Product Details
140G-G3C3-C50-KJ-MB
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
24.511
Dimension Width
21.844
Lead Time
15
Dimension Height
18.669
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40
Depth
70
Width
76.2
Device construction
Built-in device fixed built-in technique
Height
130
Factory option
Standard busbar mount, bottom ftd
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000
Weight
2.454
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
Yes
With switched-off indicator
No
Motor drive integrated
No
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 220...230V AC @ 50/60Hz
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz
Interrupting rating
65kA @ 240V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
50 A @ ambient temperature 40 °C
Construction type
T/M-fixed thermal/fixed magnetic TMF
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 11.1 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Frame size
125
Magnetic trip current (Im)
500
Thermal trip current (Ir = In (fixed))
50
Rated impulse withstand voltage (Uimp)
8
Type of control element
Toggle
Rated permanent current Iu
50
Complete device with protection unit
Yes
Integrated earth fault protection
No
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
1
Number of poles
3

Specifications may be subject to change without notice