  • 11. Thermal/Magnetic Protection: The 140G-H2C3-C30-AJ is equipped with thermal/magnetic protection, ensuring reliable operation and safety in various environmental conditions.;
  • 22. Wide Range of Mounting Options: This circuit breaker offers a variety of mounting options, making it adaptable to different panel configurations and installation requirements.;
  • 33. Global Application Certifications: Certified for global use with UL, CSA, and IEC standards, ensuring compliance and reliability in diverse applications.;
  • 44. Compact Design: The compact design of the 140G-H2C3-C30-AJ makes it space-saving, ideal for installations where space is limited.;
  • 55. High Interrupting Ratings: With high interrupting ratings, this circuit breaker provides robust protection against short circuits and overloads, ensuring the integrity of your control systems.
Product Details
140G-H2C3-C30-AJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
22.606
Dimension Width
15.24
Lead Time
16
Dimension Height
13.208
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40
Depth
82.5
Width
90
Device construction
Built-in device fixed built-in technique
Height
130
Factory option
1 NO/NC auxiliary + 1 alarm 24V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000
Weight
1.719
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
Yes
With switched-off indicator
No
Motor drive integrated
No
Protection type
T/M-fixed thermal/fixed magnetic TMF
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 65kA @ 220...230V AC, 50/60 Hz
Interrupting rating
65kA @ 240V AC, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
30 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 6.9 W
Voltage for reverse-fed circuit breaker, max
480V AC per UL/CSA
Thermal trip current (Ir)
30 A
Magnetic trip current (Im)
400 A
Frame size
125
Rated impulse withstand voltage (Uimp)
8
Type of control element
Toggle
Rated permanent current Iu
30
Complete device with protection unit
Yes
Integrated earth fault protection
No
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
1
Number of poles
3

Specifications may be subject to change without notice