Product Model
140G-H2C3-C30-AJ

Selling Points
- 11. Thermal/Magnetic Protection: The 140G-H2C3-C30-AJ is equipped with thermal/magnetic protection, ensuring reliable operation and safety in various environmental conditions.;
- 22. Wide Range of Mounting Options: This circuit breaker offers a variety of mounting options, making it adaptable to different panel configurations and installation requirements.;
- 33. Global Application Certifications: Certified for global use with UL, CSA, and IEC standards, ensuring compliance and reliability in diverse applications.;
- 44. Compact Design: The compact design of the 140G-H2C3-C30-AJ makes it space-saving, ideal for installations where space is limited.;
- 55. High Interrupting Ratings: With high interrupting ratings, this circuit breaker provides robust protection against short circuits and overloads, ensuring the integrity of your control systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 22.606 |
Dimension Width | 15.24 | Lead Time | 16 |
Dimension Height | 13.208 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Cu 75 °C |
Storage temperature | -40 | Depth | 82.5 |
Width | 90 | Device construction | Built-in device fixed built-in technique |
Height | 130 | Factory option | 1 NO/NC auxiliary + 1 alarm 24V AC/DC |
Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms | Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G |
Mechanical life operations | 25000 | Weight | 1.719 |
Degree of protection (IP) | IP40 | DIN rail (top hat rail) mounting optional | Yes |
Suitable for DIN rail (top hat rail) mounting | No | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | Yes |
With switched-off indicator | No | Motor drive integrated | No |
Protection type | T/M-fixed thermal/fixed magnetic TMF | Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 100% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only |
Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 65kA @ 220...230V AC, 50/60 Hz | Interrupting rating | 65kA @ 240V AC, 50/60 Hz per NEMA, UL, CSA |
Electrical life cycle | 8000 @ 415V AC | Thermal trip rating, max | 30 A @ ambient temperature 40 °C |
Insulation voltage (Ui) | Rated 1000V per IEC | Watt loss | Thermal magnetic type: 6.9 W |
Voltage for reverse-fed circuit breaker, max | 480V AC per UL/CSA | Thermal trip current (Ir) | 30 A |
Magnetic trip current (Im) | 400 A | Frame size | 125 |
Rated impulse withstand voltage (Uimp) | 8 | Type of control element | Toggle |
Rated permanent current Iu | 30 | Complete device with protection unit | Yes |
Integrated earth fault protection | No | With integrated under voltage release | No |
Number of auxiliary contacts as change-over contact | 1 | Number of poles | 3 |
Specifications may be subject to change without notice