Product Model
150-C9NBD

Selling Points
- 11. Efficient Motor Control: The 150-C9NBD controller ensures smooth and efficient motor operation with its advanced soft stop feature, reducing wear and tear on the motor.;
- 22. Built-in Overload Protection: Integrated overload protection prevents motor damage from excessive current, ensuring the longevity of your equipment.;
- 33. Customizable Start Times: Select from various start times (2, 5, 10, 15, 20, 25, or 30 seconds) to optimize your motor's performance based on specific application requirements.;
- 44. Reliable Operation: Designed for 3-phase motors, this controller provides reliable operation in a wide range of industrial settings, including those with varying voltage requirements (100-240V AC, 50/60 Hz).;
- 55. Easy Integration: The compact design and standardized features make it easy to integrate into existing control systems, minimizing setup time and reducing overall costs.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | STOCKED | Dimension Length | 17.297 |
Dimension Width | 18.491 | Lead Time | 5 |
Dimension Height | 9.296 | Quick Turnaround | false |
Preferred Availability | true | Repairable | NOT_REPAIRABLE |
Enclosure | Open type | Number of poles | Equipment is designed for 3-phase only for power circuit |
Mounting hole size | 4.6 mm | Pollution degree | 2 |
Altitude | 2000 m | EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 per IEC |
EMC emission levels | Radiated emission: Class A per IEC | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
Humidity | 5...95% noncondensing | Rated surrounding temperature range without derating | -5 °C |
Storage and transportation temperature | -25 °C | Steady state heat dissipation | 12 W |
Selectable soft stop | Off, 100%, 200%, or 300% of the start time setting when wired | Selectable initial torque | 15%, 25%, 35%, and 65% of locked rotor torque |
Selectable kick start - 450% FLA | 0, 0.5, 1.0, or 1.5 s | Function | Single direction |
Internal bypass | Yes | Tightening torque | 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal |
Break | TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts | Make | TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts |
Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement | Cable size | 2.5...25 mm2 (14...4 AWG) for line power terminals |
Height | 139.7 mm (5.5 in) | Depth | 110 mm (4.33 in) |
Width | 44.8 mm (1.76 in) | Shock | Opsal: 15 G |
Weight | 0.905 | Degree of protection (IP) | IP2X |
Input ON-state current (IN1, IN2) | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit | Rated control power during start without fan | 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC |
Input ON-state voltage, during start (IN1, IN2) | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit | Selectable current limit | 150%, 250%, 350%, and 450% of full load current |
Input OFF-state voltage (IN1, IN2), max | 40V AC @ 17V DC/12V AC for control circuit | Selectable start times | 2, 5, 10, 15, 20, 25, or 30 s |
Selectable overload trip class | Trip Class 10, 15, or 20 | Short circuit protection device performance (SCPD) type | Type 1 |
Integrated motor overload protection | Yes | Standard available fault current, max | 5 kA @ maximum standard fuse 60 A for delta device opsal current rating |
Standard controller feature | Soft stop | Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts |
Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts | Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts |
Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts | Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts |
Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts | High capacity available fault current, max | 69kA @ 600V, maximum current 30 A time delay Class J or Class L fuse for inside delta connected motors |
Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts | Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L |
Input OFF-state current | <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit | Rated control power during start with fan | 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC |
Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts | Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit |
Dielectric withstand | 2500V AC per IEC for power circuit | Rated impulse voltage | 6 kV for power circuit |
Overvoltage category | III per IEC for side mount auxiliary contacts | Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit |
Repetitive peak voltage | 1400V per UL/CSA/NEMA for power circuit | DV/DT protection | 1000V/μs for power circuit |
Controller type | SMC-3 | Overload current | 3 A |
Rated control supply voltage at AC 60 Hz | 100 | Rated control supply voltage at AC 50 Hz | 100 |
Rated operating voltage Ue | 200 | Voltage type for actuating | AC/DC |
With display | No | Product Family | SMC-3 |
Specifications may be subject to change without notice