Product Model
140CPU53414B

Selling Points
- 1High-Performance 80486 Processor: The 140CPU53414B features an 80486 processor running at 100 MHz, ensuring rapid execution of control algorithms and data processing.
- 2Efficient Memory Management: Equipped with 2972 kB of internal RAM, this CPU module offers ample memory capacity for storing program code, data, and configuration settings.
- 3Precise Timing and Monitoring: The watchdog timer of 250 ms and clock drift of +/-8 s/day at 0...60 °C ensure precise timing and monitoring capabilities for accurate control.
- 4Flexible I/O Configurations: Supports up to 64 inputs and 64 outputs for remote installations, with a maximum of 30 inputs and 32 outputs for distributed setups.
- 5Robust Connectivity and Networking: Facilitates seamless communication between devices and subsystems with support for up to 500 inputs and 500 outputs, and up to 63 distributed drops and 31 remote drops.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Modicon Quantum automation platform | Product or Component Type | Processor |
Software name | ProWORX 32<br />Concept | Processor name | 80486 |
Mathematical coprocessor | With | Clock frequency | 100 MHz |
Memory description | Internal RAM 2972 kB | Exact time for 1 Kinstruction | 0.1...0.5 ms LL984 |
Watchdog timer | 250 ms | Clock drift | +/-8 s/day 32…140 °F (0…60 °C) |
I/O words | 30 I/32 O distributed<br />64 I/64 O max local<br />64 I/64 O remote | I/O words/network | 500 I/500 O distributed |
Drops/network | 63 distributed | Number of drops | 31 remote |
Number of network | 2 remote<br />3 distributed | Battery type | Lithium 10 µA 420 µA |
Battery Capacity | 1.2 Ah | Battery Life | 10 year(s) |
Switch Function | Key switch | marking | CE |
Bus current requirement | 1250 mA | Module format | Standard |
Net Weight | 1.87 lb(US) (0.85 kg) | Product Certifications | FM Class 1 Division 2<br />cUL |
Standards | CSA C22.2 No 142<br />UL 508 | Resistance to electrostatic discharge | 4 kV contact IEC 801-2<br />8 kV on air IEC 801-2 |
Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 80…2000 MHz IEC 801-3 | Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) |
Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) | Relative Humidity | 95 % without condensation |
Operating altitude | <= 16404.2 ft (5000 m) |
Specifications may be subject to change without notice