Product Model
ATS01N230LY

Selling Points
- 1Efficient Motor Control: The ATS01N230LY soft starter optimizes motor performance with a voltage ramp start, reducing wear and tear.
- 2Wide Voltage Range: Compatible with 230-690 V supply voltage, making it versatile for various industrial applications.
- 3Adjustable Start Time: Starting time adjustable from 1 to 25 seconds, allowing for precise control over motor startup.
- 4High Torque Capability: Provides 30-80% of the motor's starting torque, ensuring smooth and reliable operation.
- 5Durable Construction: Built with a heat sink and robust design, ensuring long-lasting performance in demanding environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altistart 01 | Product or Component Type | Soft starter |
Product destination | Asynchronous motors | Product Specific Application | Simple machine |
Device short name | ATS01 | Phase | 3 phase |
[Us] rated supply voltage | 230...690 V - 15...10 % | Motor power kW | 15 kW, 3 phase 400 V<br />30 kW, 3 phase 690 V<br />7.5 kW, 3 phase 230 V |
Maximum Horse Power Rating | 10 hp, 3 phase 230 V<br />15 hp, 3 phase 400 V<br />20 hp, 3 phase 460 V<br />30 hp, 3 phase 575 V | IcL starter rating | 32 A |
Utilisation category | AC-53B EN/IEC 60947-4-2 | Current consumption | 90 A at nominal load |
Type of start | Start with voltage ramp | Power dissipation in W | 184 W in transient state<br />22 W at full load and at end of starting |
Assembly style | With heat sink | Function Available | Integrated bypass |
Supply voltage limits | 195…759 V | Supply frequency | 50...60 Hz - 5...5 % |
Network Frequency | 47.5...63 Hz | Output voltage | <= power supply voltage |
[Uc] control circuit voltage | 110 V AC +/- 10 % | Starting time | 1 s / 360<br />12 s / 30<br />Adjustable from 1 to 25 s |
Deceleration time symb | Adjustable from 1 to 25 s | Starting torque | 30...80 % of starting torque of motor connected directly on the line supply |
Discrete input type | Internal LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA | Discrete input voltage | 24 V |
Discrete input logic | Positive logic LI1, LI2, BOOST <= 3 V >= 10 V | Discrete output current | 2 A DC-13<br />3 A AC-15 |
Discrete output type | Relay outputs R1A, R1C | Discrete output voltage | 24 V DCrelay outputs<br />250 V ACrelay outputs |
Minimum switching current | 10 mA 17 V DC relay outputs | Display type | 1 LED Green)starter powered up<br />1 LED Yellow)nominal voltage reached |
Tightening torque | 6.2 lbf.in (0.7 N.m)<br />44.3 lbf.in (5 N.m) | Electrical connection | Earth connection: tinned connector fixed using Ø 6 mm screws<br />4 mm screw clamp terminal - rigid 1 6...35 mm² power circuit<br />Screw connector - rigid 1 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - rigid 2 6...25 mm² power circuit<br />Screw connector - rigid 2 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible with cable end 1 4...25 mm² power circuit<br />Screw connector - flexible with cable end 1 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible without cable end 1 6...25 mm² power circuit<br />Screw connector - flexible without cable end 1 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible with cable end 2 4...16 mm² power circuit<br />Screw connector - flexible with cable end 2 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible without cable end 2 6...25 mm² power circuit<br />Screw connector - flexible without cable end 2 0.75...1.5 mm² control circuit |
marking | CE | Operating position | Vertical +/- 10 degree |
Height | 5.7 in (146 mm) | Width | 7.09 in (180 mm) |
Depth | 5.0 in (126 mm) | Net Weight | 5.3 lb(US) (2.4 kg) |
Compatibility code | ATS01N2 | Electromagnetic compatibility | Conducted and radiated emissions level B IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-2<br />EMC immunity EN 50082-1<br />EMC immunity EN 50082-2<br />Harmonics IEC 1000-3-2<br />Harmonics IEC 1000-3-4<br />Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Micro-cuts and voltage fluctuation IEC 61000-4-11<br />Voltage/current impulse level 3 IEC 61000-4-5 |
Standards | EN/IEC 60947-4-2 | Product Certifications | CSA<br />C-tick<br />CCC<br />B44.1-96/ASME A17.5 for starter wired to the motor delta terminal<br />GOST<br />UL |
IP Degree of Protection | On front panel IP20 | Pollution degree | 3 IEC 60664-1<br />3 UL 508 |
Vibration resistance | 2 gn | Shock resistance | 8 gn 11 ms EN/IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation or dripping water EN/IEC 60068-2-3 | Ambient air temperature for storage | -13…158 °F (-25…70 °C) EN/IEC 60947-4-2 |
Operating altitude | <= 6561.68 ft (2000 m) without derating<br />> 6561.68 ft (2000 m) with current derating of 0.5 % per additional 100 m |
Specifications may be subject to change without notice