Selling Points

  • 1Efficient Motor Control: The ATS01N230LY soft starter optimizes motor performance with a voltage ramp start, reducing wear and tear.
  • 2Wide Voltage Range: Compatible with 230-690 V supply voltage, making it versatile for various industrial applications.
  • 3Adjustable Start Time: Starting time adjustable from 1 to 25 seconds, allowing for precise control over motor startup.
  • 4High Torque Capability: Provides 30-80% of the motor's starting torque, ensuring smooth and reliable operation.
  • 5Durable Construction: Built with a heat sink and robust design, ensuring long-lasting performance in demanding environments.
Product Details
ATS01N230LY
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altistart 01
Product or Component Type
Soft starter
Product destination
Asynchronous motors
Product Specific Application
Simple machine
Device short name
ATS01
Phase
3 phase
[Us] rated supply voltage
230...690 V - 15...10 %
Motor power kW
15 kW, 3 phase 400 V<br />30 kW, 3 phase 690 V<br />7.5 kW, 3 phase 230 V
Maximum Horse Power Rating
10 hp, 3 phase 230 V<br />15 hp, 3 phase 400 V<br />20 hp, 3 phase 460 V<br />30 hp, 3 phase 575 V
IcL starter rating
32 A
Utilisation category
AC-53B EN/IEC 60947-4-2
Current consumption
90 A at nominal load
Type of start
Start with voltage ramp
Power dissipation in W
184 W in transient state<br />22 W at full load and at end of starting
Assembly style
With heat sink
Function Available
Integrated bypass
Supply voltage limits
195…759 V
Supply frequency
50...60 Hz - 5...5 %
Network Frequency
47.5...63 Hz
Output voltage
<= power supply voltage
[Uc] control circuit voltage
110 V AC +/- 10 %
Starting time
1 s / 360<br />12 s / 30<br />Adjustable from 1 to 25 s
Deceleration time symb
Adjustable from 1 to 25 s
Starting torque
30...80 % of starting torque of motor connected directly on the line supply
Discrete input type
Internal LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA
Discrete input voltage
24 V
Discrete input logic
Positive logic LI1, LI2, BOOST <= 3 V >= 10 V
Discrete output current
2 A DC-13<br />3 A AC-15
Discrete output type
Relay outputs R1A, R1C
Discrete output voltage
24 V DCrelay outputs<br />250 V ACrelay outputs
Minimum switching current
10 mA 17 V DC relay outputs
Display type
1 LED Green)starter powered up<br />1 LED Yellow)nominal voltage reached
Tightening torque
6.2 lbf.in (0.7 N.m)<br />44.3 lbf.in (5 N.m)
Electrical connection
Earth connection: tinned connector fixed using Ø 6 mm screws<br />4 mm screw clamp terminal - rigid 1 6...35 mm² power circuit<br />Screw connector - rigid 1 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - rigid 2 6...25 mm² power circuit<br />Screw connector - rigid 2 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible with cable end 1 4...25 mm² power circuit<br />Screw connector - flexible with cable end 1 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible without cable end 1 6...25 mm² power circuit<br />Screw connector - flexible without cable end 1 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible with cable end 2 4...16 mm² power circuit<br />Screw connector - flexible with cable end 2 0.75...1.5 mm² control circuit<br />4 mm screw clamp terminal - flexible without cable end 2 6...25 mm² power circuit<br />Screw connector - flexible without cable end 2 0.75...1.5 mm² control circuit
marking
CE
Operating position
Vertical +/- 10 degree
Height
5.7 in (146 mm)
Width
7.09 in (180 mm)
Depth
5.0 in (126 mm)
Net Weight
5.3 lb(US) (2.4 kg)
Compatibility code
ATS01N2
Electromagnetic compatibility
Conducted and radiated emissions level B IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-2<br />EMC immunity EN 50082-1<br />EMC immunity EN 50082-2<br />Harmonics IEC 1000-3-2<br />Harmonics IEC 1000-3-4<br />Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Micro-cuts and voltage fluctuation IEC 61000-4-11<br />Voltage/current impulse level 3 IEC 61000-4-5
Standards
EN/IEC 60947-4-2
Product Certifications
CSA<br />C-tick<br />CCC<br />B44.1-96/ASME A17.5 for starter wired to the motor delta terminal<br />GOST<br />UL
IP Degree of Protection
On front panel IP20
Pollution degree
3 IEC 60664-1<br />3 UL 508
Vibration resistance
2 gn
Shock resistance
8 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5…95 % without condensation or dripping water EN/IEC 60068-2-3
Ambient air temperature for storage
-13…158 °F (-25…70 °C) EN/IEC 60947-4-2
Operating altitude
<= 6561.68 ft (2000 m) without derating<br />> 6561.68 ft (2000 m) with current derating of 0.5 % per additional 100 m