Product Model
ATS22D88S6

Selling Points
- 1The ATS22D88S6 soft starter provides a smooth start-up process, minimizing mechanical stresses on the motor and extending its service life.
- 2This soft starter is designed to be compact, reducing the size of enclosures and keeping temperature rises to a minimum.
- 3Equipped with integrated bypass and safety functions, it protects your installations by detecting and signaling faults such as blocked motors or underload conditions.
- 4Features a user-friendly interface with 4 LEDs, 4 navigation keys, and a 4-digit display, along with SoMove software for configuring on PC via Bluetooth or cable.
- 5Designed to operate in harsh environments with coated cards for enhanced resistance, ensuring robust and reliable performance in various applications like pumps, fans, and compressors.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altistart 22 | Product or Component Type | Soft starter |
Product destination | Asynchronous motors | Product Specific Application | Pumps and fans |
Component name | ATS22 | Phase | 3 phase |
[Us] rated supply voltage | 230...600 V - 15...10 % | Motor power kW | 22 kW 230 V<br />45 kW 400 V<br />45 kW 440 V<br />55 kW 500 V |
Factory setting current | 77 A | Power dissipation in W | 66 W for standard applications |
Utilisation category | AC-53A | Type of start | Start with torque control (current limited to 3.5 In) |
IcL starter rating | 88 A connection in the motor supply line for standard applications | IP Degree of Protection | IP20 |
Assembly style | With heat sink | Function Available | Internal bypass |
Supply voltage limits | 195…660 V | Supply frequency | 50...60 Hz - 10...10 % |
Network Frequency | 45...66 Hz | Device connection | In the motor supply line |
[Uc] control circuit voltage | 230 V - 15...10 % 50/60 Hz | Control circuit consumption | 20 W |
Discrete output number | 2 | Discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O<br />Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
Minimum switching current | 100 mA 12 V DC relay outputs) | Maximum switching current | 5 A 250 V AC resistive 1 relay outputs<br />5 A 30 V DC resistive 1 relay outputs<br />2 A 250 V AC inductive 0.4 20 ms relay outputs<br />2 A 30 V DC inductive 7 ms relay outputs |
Discrete input number | 3 | Discrete input type | LI1, LI2, LI3) logic, 5 mA 4.3 kOhm |
Discrete input voltage | 24 V <= 30 V | Discrete input logic | Positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA |
Output current | 0.4...1 Icl adjustable | PTC probe input | 750 Ohm |
communication port protocol | Modbus | Connector Type | 1 RJ45 |
Communication data link | Serial | Physical interface | RS485 multidrop |
Transmission Rate | 4800, 9600 or 19200 bps | Installed device | 31 |
Protection type | Phase failure line<br />Thermal protection motor<br />Thermal protection starter | marking | CE |
Type of cooling | Forced convection | Operating position | Vertical +/- 10 degree |
Height | 11.6 in (295 mm) | Width | 5.7 in (145 mm) |
Depth | 8.1 in (207 mm) | Net Weight | 26.5 lb(US) (12 kg) |
Motor power range AC-3 | 55…100 kW 480…500 V 3 phase<br />15…25 kW 200…240 V 3 phase<br />30…50 kW 380…440 V 3 phase | Motor starter type | Soft starter |
Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-2<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Voltage/current impulse level 3 IEC 61000-4-5 | Standards | IEC 60947-4-2 |
Product Certifications | CCC<br />GOST<br />C-tick<br />CSA<br />UL | Vibration resistance | 1 gn 13…200 Hz)IEC 60068-2-6<br />1.5 mm 2…13 Hz)IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms IEC 60068-2-27 | Noise level | 45 dB |
Pollution degree | Level 2 IEC 60664-1 | Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 |
Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating)<br />104…140 °F (40…60 °C) with current derating 2.2 % per °C) | Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Operating altitude | <= 3280.84 ft (1000 m) without derating<br />> 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m |
Specifications may be subject to change without notice