Product Model
ATS22D88S6U

Selling Points
- 1Soft start and stop functions for controlled voltage and torque.
- 2Compatible with 208-600V supply voltage.
- 3Supports motors up to 75 HP.
- 4Suitable for three-phase asynchronous motors.
- 5Automatic bypass function for seamless operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altistart 22 | Product or Component Type | Soft starter |
Product destination | Asynchronous motors | Product Specific Application | Pumps and fans |
Component name | ATS22 | Phase | 3 phase |
[Us] rated supply voltage | 208...600 V - 15...10 % | Maximum Horse Power Rating | 25 hp 208 V<br />30 hp 230 V<br />60 hp 460 V<br />75 hp 575 V |
Factory setting current | 77 A | Power dissipation in W | 66 W for standard applications |
Utilisation category | AC-53A | Type of start | Start with torque control (current limited to 3.5 In) |
IcL starter rating | 88 A connection in the motor supply line for standard applications | IP Degree of Protection | IP20 |
Assembly style | With heat sink | Function Available | Internal bypass |
Supply voltage limits | 177…660 V | Supply frequency | 50...60 Hz - 10...10 % |
Network Frequency | 45...66 Hz | Device connection | In the motor supply line |
[Uc] control circuit voltage | 110 V - 15...10 % 50/60 Hz | Control circuit consumption | 20 W |
Discrete output number | 2 | Discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O<br />Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
Minimum switching current | 100 mA 12 V DC relay outputs) | Maximum switching current | 5 A 250 V AC resistive 1 relay outputs<br />5 A 30 V DC resistive 1 relay outputs<br />2 A 250 V AC inductive 0.4 20 ms relay outputs<br />2 A 30 V DC inductive 7 ms relay outputs |
Discrete input number | 3 | Discrete input type | LI1, LI2, LI3) logic, 5 mA 20 kOhm |
Discrete input voltage | 110 V <= 121 V | Discrete input logic | Positive logic LI1, LI2, LI3 < 20 V <= 15 mA > 79 V, <= 2 mA |
Output current | 0.4...1 Icl adjustable | communication port protocol | Modbus |
Connector Type | 1 RJ45 | Communication data link | Serial |
Physical interface | RS485 multidrop | Transmission Rate | 4800, 9600 or 19200 bps |
Installed device | 31 | Protection type | Phase failure line<br />Thermal protection motor<br />Thermal protection starter |
marking | CE | Type of cooling | Forced convection |
Operating position | Vertical +/- 10 degree | Height | 11.6 in (295 mm) |
Width | 5.7 in (145 mm) | Depth | 8.1 in (207 mm) |
Net Weight | 26.5 lb(US) (12 kg) | Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-2<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Voltage/current impulse level 3 IEC 61000-4-5 |
Standards | IEC 60947-4-2 | Product Certifications | UL<br />CSA<br />GOST<br />C-tick<br />CCC |
Vibration resistance | 1 gn 13…200 Hz)IEC 60068-2-6<br />1.5 mm 2…13 Hz)IEC 60068-2-6 | Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
Noise level | 45 dB | Pollution degree | Level 2 IEC 60664-1 |
Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 | Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating)<br />104…140 °F (40…60 °C) with current derating 2.2 % per °C) |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) | Operating altitude | <= 3280.84 ft (1000 m) without derating<br />> 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m |
Specifications may be subject to change without notice