Product Model

ATV32HD11N4

In Stock
Last updated: 2025/4/29
schneider ATV32HD11N4

Selling Points

  • 1High Performance: Delivers reliable performance in demanding industrial environments with a powerful 11 kW motor.
  • 2Efficient Energy-Saving: Equipped with advanced control algorithms like flux vector control and voltage/frequency ratio control to optimize motor performance and reduce energy consumption.
  • 3Robust Construction: Built to withstand harsh industrial conditions with an IP20 degree of protection against dust and solid objects, and resistance to vibrations and shocks.
  • 4Flexible Connectivity: Supports communication protocols like CANopen and Modbus, enabling seamless integration into industrial networks for enhanced control and monitoring.
  • 5User-Friendly Interface: Features a user-friendly interface with removable screw terminals and intuitive wiring diagrams, streamlining installation and reducing downtime.
Product Details
ATV32HD11N4
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar 32
Product or Component Type
Variable speed drive
Product destination
Synchronous motors<br />Asynchronous motors
Product Specific Application
Complex machines
Function Available
-
Assembly style
With heat sink
Component name
ATV32
EMC filter
Class C2 EMC filter integrated
Phase
3 phase
[Us] rated supply voltage
380...500 V - 15...10 %
Supply voltage limits
323…550 V
Supply frequency
50...60 Hz - 5...5 %
Network Frequency
47.5...63 Hz
Motor power kW
11 kW 380...480 V
Maximum Horse Power Rating
15 hp 380...480 V
Line current
25.6 A 500 V 3 phase 11 kW / 15 hp<br />36.6 A 380 V 3 phase 11 kW / 15 hp
Apparent power
31.7 kVA 500 V 3 phase 15 kW / 20 hp
Prospective line Isc
22 kA 3 phase
Nominal output current
27.7 A 4 kHz 500 V 11 kW / 15 hp
Maximum transient current
41.6 A 60 s 11 kW / 15 hp
Output frequency
0.0005…0.599 kHz
Nominal switching frequency
4 kHz
Switching frequency
2...16 kHz adjustable
Speed range
1…100 asynchronous motor in open-loop mode
Speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
Torque accuracy
+/- 15 %
Transient overtorque
170…200 %
Braking torque
<= 170 % with braking resistor
Asynchronous motor control profile
Flux vector control without sensor, standard<br />Voltage/frequency ratio, 5 points<br />Voltage/frequency ratio, 2 points<br />Voltage/frequency ratio - Energy Saving, quadratic U/f<br />Flux vector control without sensor - Energy Saving, NoLoad law
Synchronous motor control profile
Vector control without sensor
Regulation loop
Adjustable PID regulator
Motor slip compensation
Adjustable 0...300 %<br />Automatic whatever the load<br />Not available in voltage/frequency ratio (2 or 5 points)
Local signalling
1 LED red drive voltage<br />1 LED green CANopen run<br />1 LED red CANopen error<br />1 LED red drive fault
Output voltage
<= power supply voltage
Noise level
43 dB 86/188/EEC
Insulation
Electrical between power and control
Electrical connection
Screw terminal 0.5...1.5 mm², AWG 18...AWG 14 control)<br />Removable screw terminals 6...16 mm², AWG 8...AWG 6 motor/braking resistor)<br />Screw terminal 10...16 mm², AWG 8...AWG 6 power supply)
Tightening torque
4.4 lbf.in (0.5 N.m), 4.4 lb/ft control)<br />10.6 lbf.in (1.2 N.m), 10.6 lb/ft motor/braking resistor)<br />10.6 lbf.in (1.2 N.m), 10.6 lb/ft power supply)
Supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Analogue input number
3
Analogue input type
AI1 voltage 0...10 V DC 30000 Ohm 10 bits<br />AI2 bipolar differential voltage +/- 10 V DC 30000 Ohm 10 bits<br />AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Sampling duration
2 ms AI1, AI2, AI3) - analog<br />2 ms AO1) - analog
Response time
LI1...LI6 8 ms +/- 0.7 ms logic<br />R1A, R1B, R1C 2 ms relay<br />R2A, R2C 2 ms relay
Accuracy
+/- 0.2 % AI1, AI2, AI3) for a temperature of -10...60 °C<br />+/- 0.5 % AI1, AI2, AI3) for a temperature of 25 °C<br />+/- 1 % AO1) for a temperature of 25 °C<br />+/- 2 % AO1) for a temperature of -10...60 °C
Linearity error
+/- 0.2...0.5 % of maximum value AI1, AI2, AI3)<br />+/- 0.3 % AO1)
Analogue output number
1
Analogue output type
AO1 software-configurable current 0...20 mA 800 Ohm 10 bits<br />AO1 software-configurable voltage 0...10 V 470 Ohm 10 bits
Discrete output number
3
Discrete output type
Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles<br />Configurable relay logic R2A, R2B) NO - 100000 cycles<br />Logic LO)
Minimum switching current
5 mA 24 V DC configurable relay logic
Maximum switching current
R1 3 A 250 V AC resistive, cos phi = 1<br />R1 4 A 30 V DC resistive, cos phi = 1<br />R1, R2 2 A 250 V AC inductive, cos phi = 0.4<br />R1, R2 2 A 30 V DC inductive, cos phi = 0.4<br />R2 5 A 250 V AC resistive, cos phi = 1<br />R2 5 A 30 V DC resistive, cos phi = 1
Discrete input number
7
Discrete input type
Programmable (sink/source) LI1...LI4)24...30 V DC level 1 PLC<br />Programmable as pulse input 20 kpps LI5)24...30 V DC level 1 PLC<br />Switch-configurable PTC probe LI6)24...30 V DC<br />Safe torque off STO)24...30 V DC - 1500 Ohm
Discrete input logic
Negative logic (sink) LI1...LI6), > 19 V, < 13 V<br />Positive logic (source) LI1...LI6), < 5 V, > 11 V
Acceleration and deceleration ramps
CUS<br />Deceleration ramp adaptation<br />Linear<br />Deceleration ramp automatic stop DC injection<br />S<br />Ramp switching<br />U
Braking to standstill
By DC injection
Protection type
Input phase breaks drive<br />Overcurrent between output phases and earth drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection drive
communication port protocol
CANopen<br />Modbus
Connector type
1 RJ45 on front face)Modbus/CANopen
Physical interface
2-wire RS 485 Modbus
Transmission frame
RTU Modbus
Type of polarization
No impedance Modbus
Number of addresses
1…127 CANopen<br />1…247 Modbus
Method of access
Slave CANopen
Electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test, level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test, level 3 IEC 61000-4-6<br />Electrical fast transient/burst immunity test, level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test, level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test, level 3 IEC 61000-4-3<br />Voltage dips and interruptions immunity test IEC 61000-4-11
Width
7.09 in (180 mm)
Height
15.9 in (404 mm)
Depth
9.1 in (232 mm)
Net Weight
19.2 lb(US) (8.7 kg)
Option card
Communication card CANopen daisy chain<br />Communication card CANopen open style<br />Communication card DeviceNet<br />Communication card EtherNet/IP<br />Communication card Profibus DP V1
Functionality
Mid
Specific application
Other applications
Standards
EN/IEC 61800-3<br />EN/IEC 61800-5-1<br />EN 55011 class A group 1<br />EN 61800-3 environments 1 category C2<br />EN 61800-3 environments 2 category C2
Product Certifications
CSA<br />GOST<br />UL<br />C-tick<br />NOM 117
marking
CE
Pollution degree
2 EN/IEC 61800-5-1
IP degree of protection
IP20 EN/IEC 61800-5-1
Vibration resistance
1 gn 13…200 Hz) EN/IEC 60068-2-6<br />1.5 mm peak to peak 3…13 Hz) EN/IEC 60068-2-6
Shock resistance
15 gn 11 msEN/IEC 60068-2-27
Relative humidity
5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3
Ambient air temperature for operation
14…122 °F (-10…50 °C) without derating<br />122…140 °F (50…60 °C) with derating factor
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Operating altitude
<= 3280.84 ft (1000 m) without derating<br />3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Operating position
Vertical +/- 10 degree