Product Model

ATV340D55N4E

In Stock
Last updated: 2025/4/28
schneider ATV340D55N4E

Selling Points

  • 1High Power Rating: 55 kW heavy-duty power for demanding industrial applications.
  • 2Ethernet Connectivity: Supports multiple protocols like EtherNet/IP, Modbus TCP, and more.
  • 3Versatile Motor Control: Compatible with synchronous and asynchronous motors in open and closed loop control.
  • 4Enhanced Safety Features: Includes Safe Torque Off (STO), Safe Brake Management (SBC/SBT), and other safety functions.
  • 5Durable Design: IP20 degree of protection and Class C3 EMC filter integrated for reliable operation in harsh environments.
Product Details
ATV340D55N4E
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar Machine ATV340
Product or Component Type
Variable speed drive
Product Specific Application
Machine
Mounting Mode
Wall mount
Variant
Standard version
communication port protocol
EtherNet/IP<br />Modbus TCP<br />Modbus serial
Option card
communication module, PROFINET<br /> communication module, DeviceNet<br /> communication module, CANopen<br /> communication module, EtherCAT
Phase
3 phase
Supply frequency
50...60 Hz +/- 5 %
[Us] rated supply voltage
380...480 V - 15...10 %
Nominal output current
106.0 A
Motor power kW
75 kW normal duty<br />55 kW heavy duty
Maximum Horse Power Rating
100 hp normal duty<br />75 hp heavy duty
EMC filter
Class C3 EMC filter integrated
IP degree of protection
IP20
Degree of protection
UL type 1
Discrete input number
8
Discrete input type
PTI safe torque off 0…30 kHz, 24 V DC 30 V)<br />DI1...DI5 programmable as pulse input, 24 V DC 30 V)3.5 kOhm<br /> programmable
number of preset speeds
16 preset speeds
Discrete output number
1.0
Discrete output type
Programmable output DQ1, DQ2 30 V DC 100 mA
Analogue input number
3
Analogue input type
AI1 software-configurable current 0...20 mA 250 Ohm 12 bits<br />AI1 software-configurable temperature probe or water level sensor<br />AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits<br />AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
Analogue output number
2
Analogue output type
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits<br />Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relay output number
3
Output voltage
<= power supply voltage
Relay output type
Relay outputs R1A<br />Relay outputs R1C 100000 cycles<br />Relay outputs R2A<br />Relay outputs R2C 100000 cycles
Maximum switching current
Relay output R1C resistive, cos phi = 1 3 A 250 V AC<br />Relay output R1C resistive, cos phi = 1 3 A 30 V DC<br />Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC<br />Relay output R2C resistive, cos phi = 1 5 A 250 V AC<br />Relay output R2C resistive, cos phi = 1 5 A 30 V DC<br />Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current
Relay output R1B 5 mA 24 V DC<br />Relay output R2C 5 mA 24 V DC
Physical interface
2-wire RS 485
Connector Type
3 RJ45
Method of access
Slave Modbus RTU<br />Slave Modbus TCP
Transmission Rate
4.8 kbit/s<br />9.6 kbit/s<br />19.2 kbit/s<br />38.4 kbit/s
Transmission frame
RTU
Number of addresses
1…247
Data format
8 bits, configurable odd, even or no parity
Type of polarization
No impedance
4 quadrant operation possible
True
Asynchronous motor control profile
Variable torque standard<br />Optimized torque mode<br />Constant torque standard
Synchronous motor control profile
Reluctance motor<br />Permanent magnet motor
Pollution degree
2
Maximum output frequency
0.599 kHz
Acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s<br />S, U or customized
Motor slip compensation
Not available in permanent magnet motor law<br />Automatic whatever the load<br />Can be suppressed<br />Adjustable
Switching frequency
1...8 kHz adjustable<br />2.5...8 kHz with derating factor
Nominal switching frequency
2.5 kHz
Braking to standstill
By DC injection
Brake chopper integrated
True
Line current
131.3 A 380 V with internal line choke normal duty)<br />112.7 A 480 V with internal line choke normal duty)<br />98.9 A 380 V with internal line choke heavy duty)<br />86.9 A 480 V with internal line choke heavy duty)<br />98.9 A<br />86.9 A
Maximum Input Current per Phase
131.3 A
Maximum output voltage
480 V
Apparent power
93.7 kVA 480 V normal duty)<br />72.2 kVA 480 V heavy duty)
Maximum transient current
174 A 60 s normal duty)<br />159 A 60 s heavy duty)<br />174 A 2 s normal duty)<br />159 A 2 s heavy duty)
Electrical connection
Control screw terminal 0.75...1.5 mm² AWG 18...AWG 16<br />DC bus screw terminal 70...120 mm² AWG 1/0...250 kcmil<br />Line side screw terminal 95...120 mm² AWG 3/0...250 kcmil<br />Motor screw terminal 95...120 mm² AWG 3/0...250 kcmil
Prospective line Isc
50 kA
Base load current at high overload
106.0 A
Base load current at low overload
145.0 A
Power dissipation in W
Natural convection 115 W 380 V 4 kHz heavy duty)<br />Forced convection 917 W 380 V 4 kHz heavy duty)<br />Natural convection 158 W 380 V 4 kHz normal duty)<br />Forced convection 1359 W 380 V 4 kHz normal duty)
With safety function Safely Limited Speed (SLS)
True
With safety function Safe brake management (SBC/SBT)
True
With safety function Safe Operating Stop (SOS)
False
With safety function Safe Position (SP)
False
With safety function Safe programmable logic
False
With safety function Safe Speed Monitor (SSM)
False
With safety function Safe Stop 1 (SS1)
True
With sft fct Safe Stop 2 (SS2)
False
With safety function Safe torque off (STO)
True
With safety function Safely Limited Position (SLP)
False
With safety function Safe Direction (SDI)
False
Protection type
Thermal protection motor<br />Safe torque off motor<br />Motor phase loss motor<br />Thermal protection drive<br />Safe torque off drive<br />Overheating drive<br />Overcurrent drive<br />Output overcurrent between motor phase and earth drive<br />Output overcurrent between motor phases drive<br />Short-circuit between motor phase and earth drive<br />Short-circuit between motor phases drive<br />Motor phase loss drive<br />DC Bus overvoltage drive<br />Line supply overvoltage drive<br />Line supply undervoltage drive<br />Input supply loss drive<br />Exceeding limit speed drive<br />Break on the control circuit drive
Width
10.7 in (271.0 mm)
Height
35.7 in (908.0 mm)
Depth
12.2 in (309.0 mm)
Net Weight
127.6 lb(US) (57.9 kg)
Continuous output current
145 A 4 kHz normal duty<br />106 A 4 kHz heavy duty
Operating altitude
<= 4800 m with current derating above 1000m
Operating position
Vertical +/- 10 degree
Product Certifications
UL<br />CSA<br />TÜV<br />EAC<br />CTick
marking
CE
Standards
IEC 61800-3<br />IEC 61800-5-1<br />IEC 60721-3<br />IEC 61508<br />IEC 13849-1<br />UL 618000-5-1<br />UL 508C<br />IEC 61000-3-12
Maximum THDI
<48 % full load IEC 61000-3-12<br /> <48 % 80 % load IEC 61000-3-12
Assembly style
With heat sink
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3<br />Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)
Class 3K5 according to EN 60721-3
Volume of cooling air
77932.2 Gal/hr(US) (295.0 m3/h)
Type of cooling
Forced convection
Overvoltage category
Class III
Regulation loop
Adjustable PID regulator
Noise level
62.4 dB
Ambient air transport temperature
-40…158 °F (-40…70 °C)
Ambient air temperature for operation
5…122 °F (-15…50 °C) without derating vertical position)<br />122…140 °F (50…60 °C) with derating factor vertical position)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Isolation
Between power and control terminals

Specifications may be subject to change without notice