Product Model
LC1D115T6

Selling Points
- 1Designed to withstand 8 million cycles with mechanical load, conforming to EN/ISO 13849-1.
- 2Suitable for motor control and resistive loads, with a rated operational current of 115A at ≤440V AC.
- 3Meets IEC 60947-4-1 and IEC 60947-5-1 standards, ensuring reliability and safety.
- 4Operates at 2400 cycles per hour at ≤60°C, with an inrush power of 300VA and hold-in power consumption of 22VA.
- 5Measures 6.22 inches in height, 4.72 inches in width, and 5.35 inches in depth, making it easy to integrate into various systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Range of Product | TeSys Deca |
Product or Component Type | Contactor | Device short name | LC1D |
Contactor application | Motor control<br />Resistive load | Utilisation category | AC-3<br />AC-1<br />AC-4<br />AC-3e |
Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 1000 V AC 25...400 Hz<br />Power circuit <= 300 V DC |
[Ie] rated operational current | 200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />115 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />115 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit | [Uc] control circuit voltage | 480 V AC 60 Hz |
Motor power kW | 30 kW at 220...230 V AC 50/60 Hz (AC-3)<br />55 kW at 380...400 V AC 50/60 Hz (AC-3)<br />59 kW at 415...440 V AC 50/60 Hz (AC-3)<br />75 kW at 500 V AC 50/60 Hz (AC-3)<br />80 kW at 660...690 V AC 50/60 Hz (AC-3)<br />65 kW at 1000 V AC 50/60 Hz (AC-3)<br />18.5 kW at 400 V AC 50/60 Hz (AC-4)<br />30 kW at 220...230 V AC 50/60 Hz (AC-3e)<br />55 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />59 kW at 415...440 V AC 50/60 Hz (AC-3e)<br />75 kW at 500 V AC 50/60 Hz (AC-3e)<br />80 kW at 660...690 V AC 50/60 Hz (AC-3e)<br />65 kW at 1000 V AC 50/60 Hz (AC-3e) | Maximum Horse Power Rating | 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors<br />40 hp at 230/240 V AC 50/60 Hz for 3 phase motors<br />75 hp at 460/480 V AC 50/60 Hz for 3 phase motors<br />100 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
compatibility code | LC1D | Pole contact composition | 3 NO |
Protective cover | With | [Ith] conventional free air thermal current | 200 A (at 140 °F (60 °C)) for power circuit |
Irms rated making capacity | 1260 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1 | Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 250 A 104 °F (40 °C) - 10 min for power circuit<br />550 A 104 °F (40 °C) - 1 min for power circuit<br />950 A 104 °F (40 °C) - 10 s for power circuit<br />1100 A 104 °F (40 °C) - 1 s for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit | Associated fuse rating | 250 A gG at <= 690 V coordination type 1 for power circuit<br />200 A gG at <= 690 V coordination type 2 for power circuit<br />10 A gG for signalling circuit |
Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | Power dissipation per pole | 24 W AC-1<br />7.9 W AC-3<br />7.9 W AC-3e |
[Ui] rated insulation voltage | Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL | Overvoltage category | III |
Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 8 Mcycles |
Electrical durability | 0.8 Mcycles 200 A AC-1 <= 440 V<br />0.95 Mcycles 115 A AC-3 <= 440 V<br />0.95 Mcycles 115 A AC-3e <= 440 V | Control circuit type | AC 60 Hz |
Coil technology | Without built-in suppressor module | Control circuit voltage limits | 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz<br />0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 60 Hz |
Inrush power in VA | 300 VA 60 Hz cos phi 0.8 (at 68 °F (20 °C)) | Hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) |
Heat dissipation | 3…8 W at 60 Hz | Operating time | 6...20 ms opening<br />20...50 ms closing |
Maximum operating rate | 2400 cyc/h at 60 °C | Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: solid without cable end |
Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2<br />Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 | Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 | Signalling circuit frequency | 25...400 Hz |
Minimum switching voltage | 17 V for signalling circuit | Minimum switching current | 5 mA for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit | Non-overlap time | 1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact |
Mounting Support | Rail<br />Plate | Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />IEC 60947-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1 |
Product Certifications | UL<br />CSA<br />CCC<br />UKCA<br />CE<br />EAC<br />Marine | IP degree of protection | IP20 front face IEC 60529 |
Protective treatment | THIEC 60068-2-30 | Climatic withstand | IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat |
Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating | Operating altitude | 0...9842.52 ft (0...3000 m) |
Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 | Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor closed 15 Gn for 11 ms) <br />Shocks contactor open 6 Gn for 11 ms) | Height | 6.2 in (158 mm) |
Width | 4.7 in (120 mm) | Depth | 5.4 in (136 mm) |
Net Weight | 5.5 lb(US) (2.5 kg) |
Specifications may be subject to change without notice