schneider LC1D1506CD

Selling Points

  • 1High Power Handling: Handles up to 150A and 440V for robust motor control.
  • 2Compact Design: Compact dimensions for efficient installation in control cabinets.
  • 3Versatile Coil Options: Compatible with 36V DC standard coil for diverse control needs.
  • 4Durable Construction: Built with robust materials to withstand industrial environments.
  • 5Easy Installation: Features lug/bar terminals for secure and straightforward wiring.
Product Details
LC1D1506CD
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys<br />TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor<br />Contactor
Device short name
LC1D<br />LC1D
Contactor application
Motor control<br />Resistive load<br />Resistive load<br />Motor control
Utilisation category
AC-1<br />AC-3<br />AC-3<br />AC-2
Poles description
3P<br />3P
[Ue] rated operational voltage
Power circuit <= 1000 V AC 25...400 Hz<br />Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />150 A (at <140 °F (60 °C)) AC AC-3e for power circuit<br />50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage
36 V DC<br />24 V AC 50/60 Hz
Motor power kW
75 kW at 380...400 V AC 50 Hz<br />80 kW at 415...440 V AC 50 Hz<br />90 kW at 500 V AC 50 Hz<br />100 kW at 660...690 V AC 50 Hz<br />90 kW at 1000 V AC 50 Hz<br />40 kW at 220...230 V AC 50 Hz<br />22 kW at 380...400 V AC 50 Hz (AC-3)<br />25 kW at 415 V AC 50 Hz (AC-3)
Maximum Horse Power Rating
40 hp at 200/208 V AC 60 Hz for 3 phase motors<br />50 hp at 230/240 V AC 60 Hz for 3 phase motors<br />100 hp at 460/480 V AC 60 Hz for 3 phase motors<br />125 hp at 575/600 V AC 60 Hz for 3 phase motors<br />3 hp at 115 V AC 60 Hz for 1 phase motors<br />7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
compatibility code
LC1D<br />LC1D
Pole contact composition
3 NO<br />3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit<br />200 A (at 140 °F (60 °C)) for power circuit<br />80 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
250 A DC for control circuit conforming to IEC 60947-5-1<br />1660 A at 440 V for power circuit conforming to IEC 60947<br />900 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity
1400 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1<br />250 A gG at <= 690 V coordination type 2 for power circuit<br />315 A gG at <= 690 V coordination type 1 for power circuit
Power dissipation per pole
24 W AC-1<br />13.5 W AC-3<br />13.5 W AC-3e
[Ui] rated insulation voltage
Control circuit 600 V CSA<br />Control circuit 600 V UL<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Control circuit 690 V IEC 60947-1<br />Power circuit 1000 V IEC 60947-1
Overvoltage category
III<br />III
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
8 Mcycles<br />15000000 cycles
Control circuit type
DC standard<br />AC 50/60 Hz
Coil technology
With integral suppression device<br />Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.15...0.4 Uc -40…158 °F (-40…70 °C) drop-out DC<br />0.75...1.2 Uc -40…131 °F (-40…55 °C) operational DC<br />1...1.2 Uc 131…158 °F (55…70 °C) operational DC<br />0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
Inrush power in W
270…365 W 68 °F (20 °C))
Hold-in power consumption in VA
13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))<br />15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power consumption in W
2.4…5.1 W 68 °F (20 °C)
Heat dissipation
3…4.5 W at 50/60 Hz for control circuit
Operating time
20...35 ms closing<br />40...75 ms opening<br />4...19 ms opening<br />12...26 ms closing
Time constant
25 ms
Maximum operating rate
1200 cyc/h at 60 °C
Connections - terminals
Control circuit: lugs - external diameter: 0.3 in (8 mm)<br />Power circuit: lugs - external diameter: 1.0 in (25 mm)<br />Power circuit: bars - busbar cross section: 5 x 25 mm<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) lugs Philips No 2<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs flat Ø 6 mm<br />Power circuit 106.2 lbf.in (12 N.m) hexagonal 0.5 in (13 mm)<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs pozidriv No 2<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts
Mounting Support
Rail<br />Plate<br />Plate<br />Rail
Standards
CSA C22.2 No 14<br />EN 60947-4-1<br />IEC 60947-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1
Product Certifications
UL<br />CCC<br />CSA<br />CE<br />UKCA<br />Marine<br />EAC
IP degree of protection
IP2X IEC 60529<br />IP2X VDE 0106
Climatic withstand
IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor closed 15 Gn for 11 ms) <br />Shocks contactor opened 6 Gn for 11 ms) <br />Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor opened 10 Gn for 11 ms)
Height
6.2 in (158 mm)<br />4.8 in (122 mm)
Width
4.7 in (120 mm)<br />2.2 in (55 mm)
Depth
5.2 in (132 mm)<br />4.7 in (120 mm)
Net Weight
5.5 lb(US) (2.5 kg)<br />3.09 lb(US) (1.4 kg)
Quantity per Set
Set of 10

Specifications may be subject to change without notice