schneider LC1D656M7

Selling Points

  • 1Designed to withstand harsh industrial conditions, ensuring consistent performance.
  • 2Optimized for energy efficiency, reducing operational costs and environmental impact.
  • 3Suitable for a wide range of industrial applications, including manufacturing and automation.
  • 4Equipped with cutting-edge technology for precise control and monitoring.
  • 5Backed by Schneider Electric's extensive support network for seamless integration and maintenance.
Product Details
LC1D656M7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-2<br />AC-3<br />AC-1
Poles description
4P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage
72 V DC
Motor power kW
37 kW at 500 V AC 50 Hz<br />37 kW at 660...690 V AC 50 Hz<br />18.5 kW at 220...230 V AC 50 Hz<br />30 kW at 415 V AC 50 Hz<br />37 kW at 1000 V AC 50 Hz<br />7.5 kW at 500 V AC 50 Hz<br />7.5 kW at 660...690 V AC 50 Hz
Maximum Horse Power Rating
20 hp at 200/208 V AC 60 Hz for 3 phase motors<br />20 hp at 230/240 V AC 60 Hz for 3 phase motors<br />40 hp at 460/480 V AC 60 Hz for 3 phase motors<br />50 hp at 575/600 V AC 60 Hz for 3 phase motors<br />0.5 hp at 115 V AC 60 Hz for 1 phase motors<br />2 hp at 230/240 V AC 60 Hz for 1 phase motors
compatibility code
LC1D
Pole contact composition
4 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit<br />25 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
250 A at 440 V for power circuit conforming to IEC 60947<br />250 A DC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity
250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
105 A 104 °F (40 °C) - 10 s for power circuit<br />210 A 104 °F (40 °C) - 1 s for power circuit
Associated fuse rating
125 A gG at <= 690 V coordination type 2 for power circuit<br />10 A gG for control circuit conforming to IEC 60947-5-1<br />25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole
1.56 W AC-1
[Ui] rated insulation voltage
Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Control circuit 690 V IEC 60947-1<br />Power circuit 690 V IEC 60947-1<br />Control circuit 600 V CSA<br />Control circuit 600 V UL
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
30000000 cycles
Control circuit type
DC standard
Coil technology
Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz<br />1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz<br />0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC<br />0.7...1.25 Uc -40…140 °F (-40…60 °C) operational DC
Inrush power in W
5.4 W 68 °F (20 °C))
Hold-in power consumption in W
5.4 W 68 °F (20 °C)
Operating time
20 ms opening<br />63 ms closing
Time constant
28 ms
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Power circuit: spring terminals 1 0.004 in² (2.5 mm²) - cable stiffness: flexible without cable end<br />Power circuit: spring terminals 2 0.004 in² (2.5 mm²) - cable stiffness: flexible without cable end
Tightening torque
Power circuit 22.1 lbf.in (2.5 N.m) lugs flat Ø 8 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Terminals description ISO n°1
(13-14)NO
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts
Mounting Support
Plate<br />Rail
Standards
EN 60947-5-1<br />EN 60947-4-1<br />UL 508<br />CSA C22.2 No 14<br />IEC 60947-5-1<br />IEC 60947-4-1
Product Certifications
LROS (Lloyds register of shipping)<br />RINA<br />UL<br />DNV<br />GOST<br />CCC<br />GL<br />GOST<br />CSA
IP degree of protection
IP2X IEC 60529<br />IP2X VDE 0106
Climatic withstand
IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor opened 10 Gn for 11 ms) <br />Shocks contactor closed 15 Gn for 11 ms)
Height
3.9 in (99 mm)
Width
1.8 in (45 mm)
Depth
3.9 in (99 mm)
Net Weight
1.19 lb(US) (0.54 kg)

Specifications may be subject to change without notice