schneider LC1F4004F7

Selling Points

  • 1High-Power AC-1 Capability: Handles up to 500 A at 440 V AC.
  • 2Efficient Operation: Operates at 40-400 Hz with low inrush power (1075 VA) and hold-in power (15 VA).
  • 3Reliable Insulation: Rated for 1000 V AC and 1500 V DC insulation voltage.
  • 4Durable Design: Meets IEC 60947-4-1 standards with a rated short-time withstand current of 3600 A.
  • 5Versatile Connectivity: Features screw clamp terminals for flexible cable connections.
Product Details
LC1F4004F7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
110 V AC 40...400 Hz
[Ie] rated operational current
500 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
500 A (at 104 °F (40 °C))
Rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A 104 °F (40 °C) - 10 s<br />2400 A 104 °F (40 °C) - 30 s<br />1700 A 104 °F (40 °C) - 1 min<br />1200 A 104 °F (40 °C) - 3 min<br />1000 A 104 °F (40 °C) - 10 min
Associated fuse rating
400 A aM at <= 440 V<br />500 A gG at <= 440 V
Average impedance
0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
65 W AC-1
Overvoltage category
III
power pole contact composition
4 NO
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in VA
1075 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
15 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
40...65 ms closing<br />100...170 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 30 x 5 mm<br />Power circuit lugs-ring terminals 2 0.2 in² (150 mm²)<br />Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
14 W
Standards
JIS C8201-4-1<br />EN 60947-4-1<br />IEC 60947-1<br />IEC 60947-4-1<br />EN 60947-1
Product Certifications
RINA<br />RMRoS<br />CB<br />CCC<br />DNV<br />ABS<br />LROS (Lloyds register of shipping)<br />BV<br />UL<br />UKCA
Compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Height
8.1 in (206 mm)
Width
10.3 in (261 mm)
Depth
8.6 in (219 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
22.5 lb(US) (10.2 kg)

Specifications may be subject to change without notice