schneider LC1G630LSEN

Selling Points

  • 1High power handling with up to 630A and 400kW@440V.
  • 2Designed for demanding applications with maximum operating rates up to 600 cycles per hour.
  • 3Embedded highly reliable 1NO+1NC auxiliary contact block for enhanced functionality.
  • 4Compact size with dimensions 324mm x 210mm x 248mm, enabling panel space savings.
  • 5Multi-standard certified (CE, CB, CCC, cULus, EAC, KC, RCM) and Green Premium compliant (RoHs/Reach).
Product Details
LC1G630LSEN
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Giga
Product or Component Type
Contactor
Device short name
LC1G
Contactor application
Power switching<br />Motor control
Utilisation category
AC-1<br />AC-3<br />AC-3e<br />AC-4<br />AC-5a<br />AC-5b<br />AC-6a<br />AC-6b<br />AC-8a<br />AC-8b<br />DC-1<br />DC-3<br />DC-5
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /> <= 460 V DC
[Ie] rated operational current
1050 A (at <104 °F (40 °C)) at <= 1000 V AC-1<br />630 A (at <140 °F (60 °C)) at <= 440 V AC-3
[Uc] control circuit voltage
200...500 V AC 50/60 Hz<br />200...500 V DC
Control circuit voltage limits
Operational: 0.8 Uc Min...1.1 Uc Max (at <140 °F (60 °C))<br />Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
1050 A (at 104 °F (40 °C))
Rated breaking capacity
5550 A at 440 V
[Icw] rated short-time withstand current
5.05 kA - 10 s<br />4.4 kA - 30 s<br />3.4 kA - 1 min<br />2.2 kA - 3 min<br />1.6 kA - 10 min
Associated fuse rating
630 A aM at <= 440 V for motor<br />500 A aM at <= 690 V for motor<br />1250 A gG at <= 690 V
Average impedance
0.000065 Ohm
[Ui] rated insulation voltage
1000 V
Power dissipation per pole
70 W AC-1 - Ith 1050 A<br />26 W AC-3 - Ith 630 A
compatibility code
LC1G
Pole contact composition
3 NO
Auxiliary contact composition
1 NO + 1 NC
Motor power kW
180 kW at 230 V AC 50/60 Hz (AC-3e)<br />315 kW at 400 V AC 50/60 Hz (AC-3e)<br />335 kW at 415 V AC 50/60 Hz (AC-3e)<br />355 kW at 440 V AC 50/60 Hz (AC-3e)<br />375 kW at 500 V AC 50/60 Hz (AC-3e)<br />500 kW at 690 V AC 50/60 Hz (AC-3e)<br />450 kW at 1000 V AC 50/60 Hz (AC-3e)<br />200 kW at 230 V AC 50/60 Hz (AC-3)<br />335 kW at 400 V AC 50/60 Hz (AC-3)<br />375 kW at 415 V AC 50/60 Hz (AC-3)<br />400 kW at 440 V AC 50/60 Hz (AC-3)<br />400 kW at 500 V AC 50/60 Hz (AC-3)<br />500 kW at 690 V AC 50/60 Hz (AC-3)<br />450 kW at 1000 V AC 50/60 Hz (AC-3)<br />180 kW at 230 V AC 50/60 Hz (AC-4)<br />315 kW at 400 V AC 50/60 Hz (AC-4)<br />335 kW at 415 V AC 50/60 Hz (AC-4)<br />355 kW at 440 V AC 50/60 Hz (AC-4)<br />375 kW at 500 V AC 50/60 Hz (AC-4)<br />450 kW at 690 V AC 50/60 Hz (AC-4)<br />355 kW at 1000 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating
250 hp at 200/208 V 60 Hz<br />300 hp at 230/240 V 60 Hz<br />600 hp at 460/480 V 60 Hz<br />700 hp at 575/600 V 60 Hz
Irms rated making capacity
7220 A at 440 V
Coil technology
Built-in bidirectional peak limiting
Safety reliability level
B10d = 100000 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 1800000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
5 Mcycles
inrush power in VA (50/60 Hz, AC)
670 VA
inrush power in W (DC)
390 W
hold-in power consumption in VA (50/60 Hz, AC)
17 VA
hold-in power consumption in W (DC)
11 W
Operating time
40...70 ms closing<br />15...50 ms opening
Maximum operating rate
600 cyc/h AC-3<br />600 cyc/h AC-3e<br />300 cyc/h AC-1<br />150 cyc/h AC-4
Connections - terminals
Power circuit: bar 2 - busbar cross section: 52 x 20 mm<br />Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²)<br />Power circuit: bolted connection<br />Control circuit: push-in 1 0.0003…0.004 in² (0.2…2.5 mm²) - cable stiffness: solid stranded without cable end<br />Control circuit: push-in 1 0.0004…0.004 in² (0.25…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: push-in 2 0.0008…0.002 in² (0.5…1.0 mm²) with cable end<br />Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) - cable stiffness: solid stranded without cable end<br />Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) - cable stiffness: flexible with cable end
Connection pitch
2.8 in (70 mm)
Mounting Support
Plate
Standards
EN/IEC 60947-4-1<br />EN/IEC 60947-5-1<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1<br />JIS C8201-5-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-1<br />UL 60335-2-40:Annex JJ
Product Certifications
CB Scheme<br />CCC<br />cULus<br />EAC<br />CE<br />UKCA<br />EU-RO-MR by DNV-GL
Tightening torque
513.3 lbf.in (58 N.m)
Height
11.2 in (284 mm)
Width
8.3 in (211 mm)
Depth
10.5 in (266 mm)
Net Weight
31.3 lb(US) (14.2 kg)
IP degree of protection
IP2X front face with shrouds IEC 60529<br />IP2X front face with shrouds VDE 0106
Ambient Air Temperature for Operation
-13…140 °F (-25…60 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Mechanical robustness
Vibrations 5…300 Hz 2 gn contactor open<br />Vibrations 5…300 Hz 4 gn contactor closed<br />Shocks 10 gn 11 ms contactor open<br />Shocks 15 gn 11 ms contactor closed
color
Dark grey
Protective treatment
TH
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C) at Uc

Specifications may be subject to change without notice