Product Model
TM172E12R

Selling Points
- 1High efficiency design for reduced energy consumption.
- 2Robust construction for reliable operation in harsh environments.
- 3Advanced thermal management for optimal performance.
- 4Compact size for easy integration into various systems.
- 5Compliance with international safety standards for secure use.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Modicon M171/M172 | Product or Component Type | Additional I/O module |
Product Specific Application | HVAC control | Total inputs/outputs | 12 |
Discrete input number | 2 | Discrete output number | 3 relay outputs SPST with same common |
Discrete output current | 3 A relay SPST | Analogue input number | 4 configurable by pair |
Number of port | 1 CAN port - screw terminal block | Input/output number | 6 digital output<br />4 analog input<br />2 digital input |
Discrete input logic | Positive logic (sink) up to 2 kHz | Discrete input voltage | 24 V AC/DC |
Discrete input current | 2.5 mA AC/DC | input impedance | 20 kOhm |
Analogue input type | NTC NK103 Beta 3977 temperature probe - 40...137 °C 0.1 °C 10 kOhm at 25 °C)<br />NTC 103AT-2 Beta 3435 temperature probe - 50...110 °C 0.1 °C 10 kOhm at 25 °C)<br /> current 0...20 mA 1 digit < 150 Ohm<br /> current 4...20 mA 1 digit < 150 Ohm<br /> voltage 0...10 V 1 digit > 10 kOhm<br /> voltage 0...5 V 1 digit > 20 kOhm absolute or ratiometric)<br /> impedance 0...1500 hOhm 1 hOhm 10 kOhm<br /> impedance 0...300 daOhm 1 daOhm 2 kOhm<br />Pt 100/Pt 1000 PTC - 55...150 °C 0.1 °C 2 kOhm<br /> direct input 1 digit Dry contact)<br /> Pt 1000 temperature probe - 200...850 °C 0.1 °C 2 kOhm | Measurement accuracy | NTC NK103 - 40...+110 °C +/- 1 °C<br /> NTC NK103 110...137 °C +/- 1.9 °C<br /> NTC 103AT-2 - 50…110 °C +/- 1 °C<br /> PTC - 55...+135 °C +/- 1.1 °C<br /> PTC - 150…135 °C +/- 3.1 °C<br /> Pt 1000 - 200...-100 °C +/- 5 °C<br /> Pt 1000 - 100...-50 °C +/- 3 °C<br /> Pt 1000 - 50...+200 °C +/- 1.5 °C<br /> Pt 1000 200...600 °C +/- 15 °C<br /> Pt 1000 600...850 °C +/- 30 °C<br />0...20 mA 0...4 mA +/- 2 % of full scale +/- 1 digit<br />0...20 mA 4...20 mA +/- 1 % of full scale +/- 1 digit<br />4...20 mA +/- 1 % of full scale +/- 1 digit<br />0...10 V +/- 1 % of full scale +/- 1 digit<br />0...5 V +/- 1 % of full scale +/- 1 digit<br />HOhm 0...700 hOhm +/- 10 hOhm<br />HOhm 700 hOhm...1200 hOhm +/- 25 hOhm<br />HOhm 1200 hOhm...1500 hOhm +/- 60 hOhm<br />DaOhm 0...300 daOhm +/- 2.5 daOhm |
Sensor power supply | 5 V DC 50 mA<br />24 V DC 125 mA | [Us] rated supply voltage | 24 V +/- 10 % AC<br />20...38 V DC |
Power consumption in W | 20 VA 24 V AC<br />10 W 24 V DC | Realtime clock | Without clock |
Display type | Without Display | Overvoltage category | II |
Mounting Support | Panel mounting with accessory<br />DIN rail | Width | 2.8 in (72 mm) |
Height | 4.3 in (110 mm) | Depth | 2.3 in (59 mm) |
Net Weight | 0.31 lb(US) (0.14 kg) | Directives | 2014/35/EU - low voltage directive<br />2014/30/EU - electromagnetic compatibility |
Standards | IEC 61000-4-11<br />EN 60068-2-6 Fc<br />IEC 61000-4-5<br />EN 60730-2-9<br />EN 60730-1<br />IEC 61000-4-2<br />UL 60730-2-9<br />IEC 61000-4-4<br />CSA E60730-2-9<br />CAN/CSA-E60730-1<br />IEC 61000-4-3<br />EN 60068-2-27<br />UL94 (material V0) | Product Certifications | CE<br />RCM<br />cURus<br />CSA<br />EAC |
Ambient air temperature for operation | -4…149 °F (-20…65 °C) UL 60730-1 | Ambient Air Temperature for Storage | -22…158 °F (-30…70 °C) |
Relative humidity | 5…95 % non-condensing | IP degree of protection | IP20 |
Pollution degree | 2 |
Specifications may be subject to change without notice