Product Model
XB5AS86449B4

Selling Points
- 1Illuminated Design: Enhances visibility in low-light environments.
- 2Trigger Latching Turn: Ensures secure operation with a turn-to-release mechanism.
- 324V DC Operation: Compatible with a wide range of industrial power systems.
- 4Red Mushroom Head: Durable and easy-to-use design.
- 51NO + 2NC Contacts: Provides reliable electrical switching functionality.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Harmony XB5 | Product or Component Type | Illuminated emergency stop push-button |
Device short name | XB5 | Bezel material | Plastic |
Fixing collar material | Plastic | Head type | Standard |
Mounting diameter | 0.9 in (22 mm) | Sale per indivisible quantity | 1 |
Local signalling | 1 red LED 24 V DC7.5 mA | Light source | LED |
[Us] rated supply voltage | 24 V DC 50 Hz | Light source colour | Red |
Service life in hours | 30000 h 77 °F (25 °C) | Shape of signaling unit head | Round |
Type of operator | trigger action and mechanical latching with mechanical state indicator | Reset | Turn to release |
Operator profile | Red mushroom Ø 40 mm, unmarked | Contact operation | Slow-break |
Connections - terminals | Screw clamp terminals, <= 1.25 mm² with cable end IEC 60947-1<br />Screw clamp terminals, <= 1.25 mm² without cable end IEC 60947-1 | Device presentation | Complete product |
Supply voltage limits | 21.6…26.4 V DC | Height | 1.7 in (42 mm) |
Width | 1.7 in (42 mm) | Depth | 3.1 in (79.5 mm) |
Terminals description ISO n°1 | (21-22)NC<br />(11-12)NC<br />(13-14)NO | Net Weight | 0.207 lb(US) (0.094 kg) |
Contacts usage | Monitoring contact | Positive opening | With IEC 60947-5-1 appendix K |
Mechanical durability | 100000 cycles | Tightening torque | 7.08…13.3 lbf.in (0.8…1.5 N.m) IEC 60947-1 |
Shape of screw head | Slotted flat Ø 5.5 mm<br />Cross JIS No 2<br />Cross Philips No 2 | Contacts material | Silver alloy - gold plated (Ag/Cu) |
Short-circuit protection | 10 A cartridge fuse gG IEC 60947-5 | [Ith] conventional free air thermal current | 5 A IEC 60947-5-1 |
[Ui] rated insulation voltage | 250 V 2)IEC 61140 | [Uimp] rated impulse withstand voltage | 2.5 kV IEC 60947-1 |
[Ie] rated operational current | 1.5 A 240 V, AC-15, B300 IEC 60947-5-1<br />3 A 120 V, AC-15, B300 IEC 60947-5-1<br />0.1 A 250 V, DC-13, R300 IEC 60947-5-1<br />0.22 A 125 V, DC-13, R300 IEC 60947-5-1 | Electrical durability | 100000 cycles, AC-15, 1.5 A 240 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C<br />100000 cycles, AC-15, 3 A 120 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C<br />100000 cycles, DC-13, 0.1 A 250 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C<br />100000 cycles, DC-13, 0.22 A 125 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C |
Ambient Air Temperature for Storage | -40…176 °F (-40…80 °C) | Ambient Air Temperature for Operation | -4…122 °F (-20…50 °C) |
Overvoltage category | Class II IEC 61140 | IP degree of protection | IP65 IEC 60529 front face)<br />IP2X back face) |
Standards | IEC 60947-1<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />IEC 60947-5-5<br />IEC 60204-1<br />ISO 13850<br />JIS C8201-5-1<br />UL 508<br />JIS C8201-1 | Product Certifications | UL Listed<br />CSA |
Vibration resistance | 50 m/s² 10…500 Hz)IEC 60068-2-6 | Shock resistance | 150 m/s² 11 ms) half sine wave acceleration IEC 60068-2-27 |
Specifications may be subject to change without notice