schneider XB5AS86449B4

Selling Points

  • 1Illuminated Design: Enhances visibility in low-light environments.
  • 2Trigger Latching Turn: Ensures secure operation with a turn-to-release mechanism.
  • 324V DC Operation: Compatible with a wide range of industrial power systems.
  • 4Red Mushroom Head: Durable and easy-to-use design.
  • 51NO + 2NC Contacts: Provides reliable electrical switching functionality.
Product Details
XB5AS86449B4
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB5
Product or Component Type
Illuminated emergency stop push-button
Device short name
XB5
Bezel material
Plastic
Fixing collar material
Plastic
Head type
Standard
Mounting diameter
0.9 in (22 mm)
Sale per indivisible quantity
1
Local signalling
1 red LED 24 V DC7.5 mA
Light source
LED
[Us] rated supply voltage
24 V DC 50 Hz
Light source colour
Red
Service life in hours
30000 h 77 °F (25 °C)
Shape of signaling unit head
Round
Type of operator
trigger action and mechanical latching with mechanical state indicator
Reset
Turn to release
Operator profile
Red mushroom Ø 40 mm, unmarked
Contact operation
Slow-break
Connections - terminals
Screw clamp terminals, <= 1.25 mm² with cable end IEC 60947-1<br />Screw clamp terminals, <= 1.25 mm² without cable end IEC 60947-1
Device presentation
Complete product
Supply voltage limits
21.6…26.4 V DC
Height
1.7 in (42 mm)
Width
1.7 in (42 mm)
Depth
3.1 in (79.5 mm)
Terminals description ISO n°1
(21-22)NC<br />(11-12)NC<br />(13-14)NO
Net Weight
0.207 lb(US) (0.094 kg)
Contacts usage
Monitoring contact
Positive opening
With IEC 60947-5-1 appendix K
Mechanical durability
100000 cycles
Tightening torque
7.08…13.3 lbf.in (0.8…1.5 N.m) IEC 60947-1
Shape of screw head
Slotted flat Ø 5.5 mm<br />Cross JIS No 2<br />Cross Philips No 2
Contacts material
Silver alloy - gold plated (Ag/Cu)
Short-circuit protection
10 A cartridge fuse gG IEC 60947-5
[Ith] conventional free air thermal current
5 A IEC 60947-5-1
[Ui] rated insulation voltage
250 V 2)IEC 61140
[Uimp] rated impulse withstand voltage
2.5 kV IEC 60947-1
[Ie] rated operational current
1.5 A 240 V, AC-15, B300 IEC 60947-5-1<br />3 A 120 V, AC-15, B300 IEC 60947-5-1<br />0.1 A 250 V, DC-13, R300 IEC 60947-5-1<br />0.22 A 125 V, DC-13, R300 IEC 60947-5-1
Electrical durability
100000 cycles, AC-15, 1.5 A 240 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C<br />100000 cycles, AC-15, 3 A 120 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C<br />100000 cycles, DC-13, 0.1 A 250 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C<br />100000 cycles, DC-13, 0.22 A 125 V 1800 cyc/h 0.4 IEC 60947-5-1 appendix C
Ambient Air Temperature for Storage
-40…176 °F (-40…80 °C)
Ambient Air Temperature for Operation
-4…122 °F (-20…50 °C)
Overvoltage category
Class II IEC 61140
IP degree of protection
IP65 IEC 60529 front face)<br />IP2X back face)
Standards
IEC 60947-1<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />IEC 60947-5-5<br />IEC 60204-1<br />ISO 13850<br />JIS C8201-5-1<br />UL 508<br />JIS C8201-1
Product Certifications
UL Listed<br />CSA
Vibration resistance
50 m/s² 10…500 Hz)IEC 60068-2-6
Shock resistance
150 m/s² 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice