schneider XB5AW3665

Selling Points

  • 1High-quality industrial-grade components for durability and reliability.
  • 2Designed for efficient performance in various industrial settings.
  • 3Easy installation and maintenance to minimize downtime.
  • 4Compatible with a wide range of applications, including automation and control systems.
  • 5Enhanced safety features to ensure safe operation in demanding environments.
Product Details
XB5AW3665
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB5
Product or Component Type
Illuminated push-button
Device short name
XB5
Bezel material
Plastic
Fixing collar material
Plastic
Mounting diameter
0.9 in (22 mm)
Sale per indivisible quantity
1
Shape of signaling unit head
Round
Type of operator
spring return
Operator profile
Blue flush, unmarked
Operator additional information
With plain lens
Contacts type and composition
1 NO + 1 NC
Contact operation
Slow-break
[Us] rated supply voltage
<= 250 V
cap/operator or lens colour
Blue
Terminals description ISO n°1
(13-14)NO<br />(21-22)NC
Resistance to high pressure washer
1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Contacts usage
Standard contacts
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)<br />0.1 in (2.6 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating force
3.5 N NC changing electrical state<br />3.8 N
Mechanical durability
5000000 cycles
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw head
Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
10 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV EN/IEC 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A600 EN/IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Λ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4<br />Λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
Signalling type
Steady
current consumption
18 mA
Service life
100000 h at rated voltage and 25 °C
Surge withstand
1 kV IEC 61000-4-5
Device presentation
Complete product
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Overvoltage category
Class II IEC 60536
IP degree of protection
IP66 IEC 60529
NEMA degree of protection
NEMA 13<br />NEMA 4X
IK degree of protection
IK05 conforming to IEC 50102
Product Certifications
CSA<br />UL Listed<br />BV<br />GL<br />DNV<br />LROS (Lloyds register of shipping)
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Resistance to fast transients
2 kV IEC 61000-4-4
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge
6 kV on contact (on metal parts) IEC 61000-4-2<br />8 kV in free air (in insulating parts) IEC 61000-4-2
Electromagnetic emission
Class B IEC 55011

Specifications may be subject to change without notice