Product Model
XB5FD25

Selling Points
- 1High-quality components ensure long-lasting performance.
- 2Compact design for easy installation in tight spaces.
- 3Advanced thermal management for optimal cooling.
- 4Meets or exceeds international safety standards.
- 5Compatible with a wide range of electrical systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Harmony XB5 | Product or Component Type | Selector switch |
Device short name | XB5F | Bezel material | Dark grey plastic |
Head type | Built-in-flush | Mounting diameter | 1.2 in (30.5 mm) |
Sale per indivisible quantity | 1 | Shape of signaling unit head | Round |
Type of operator | stay put | Operator profile | Black standard handle, unmarked |
Operator position information | 2 positions 90° | Contacts type and composition | 1 NO + 1 NC |
Contact operation | Slow-break | Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1 |
Height | 1.7 in (42 mm) | Width | 1.4 in (36.6 mm) |
Depth | 2.9 in (73 mm) | Terminals description ISO n°1 | (21-22)NC<br />(13-14)NO |
Resistance to high pressure washer | 1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m | Contacts usage | Standard contacts |
Positive opening | With NC contact IEC 60947-5-1 appendix K | Mechanical durability | 1000000 cycles |
Tightening torque | 7.08…10.6 lbf.in (0.8…1.2 N.m) IEC 60947-1 | Shape of screw head | Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm |
Contacts material | Silver alloy (Ag/Ni) | Short-circuit protection | 10 A cartridge fuse gG IEC 60947-5-1 |
[Ith] conventional free air thermal current | 10 A IEC 60947-5-1 | [Ui] rated insulation voltage | 600 V 3)IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60947-1 | [Ie] rated operational current | 3 A 240 V, AC-15, A600 IEC 60947-5-1<br />6 A 120 V, AC-15, A600 IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 IEC 60947-5-1 |
Electrical durability | 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C | Electrical reliability | Λ < 10exp(-6) 5 V, 1 mA in clean environment IEC 60947-5-4<br />Λ < 10exp(-8) 17 V, 5 mA in clean environment IEC 60947-5-4 |
Device presentation | Complete product | Protective treatment | TH |
Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) |
Electrical shock protection class | Class II IEC 60536 | IP degree of protection | IP66 IEC 60529<br />IP67<br />IP69<br />IP69K |
NEMA degree of protection | NEMA 13<br />NEMA 4X | IK degree of protection | IK03 conforming to IEC 50102 |
Standards | IEC 60947-1<br />UL 508<br />JIS C8201-5-1<br />IEC 60947-5-4<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C8201-1<br />ISO 21702<br />ISO 22196:2011 | Product Certifications | UL Listed<br />CSA |
Vibration resistance | 5 gn 2…500 Hz)IEC 60068-2-6 | Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Specifications may be subject to change without notice