schneider XB6EDW4J1P

Selling Points

  • 1Robust IP65 Protection: Ensures complete protection against solid particles and a good level of protection against water.
  • 2Easy Installation: Simple to install with a clip-together component system, making it quick and efficient.
  • 3Reliable Operation: Designed for operation in temperatures ranging from -13 to 122°F (-25 to 50°C) and storage up to 158°F (70°C).
  • 4High-Brightness LED: Features super-bright, true-color LED light for clear indication of machine status.
  • 5Versatile Applications: Suitable for various applications including control panels, surveillance rooms, alarms, and medical instrumentation.
Product Details
XB6EDW4J1P
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB6E
Product or Component Type
Illuminated monolithic push-button
Device short name
XB6E
Bezel material
Plastic
Mounting diameter
0.6 in (16 mm)
Sale per indivisible quantity
5
Shape of signaling unit head
Rectangular
Type of operator
spring return
Operator profile
Red flush
Contacts type and composition
1 C/O
Contact operation
Snap action
Connections - terminals
Insulated faston 2.8 x 0.5 mm<br />Solder terminal <= 0.75 mm² AWG 19<br />Fast connector socket
Contacts material
Gold-flashed silver
Light source
Integral LED
[Us] rated supply voltage
12 V DC polarised
Net Weight
0.013 lb(US) (0.006 kg)
Operating position
Any position
marking
CE
Mechanical durability
1000000 cycles
Contact resistance
50 mOhm 1/6 V
Short-circuit protection
2 A cartridge fuse gG
[Ith] conventional free air thermal current
3 A fast connector socket)<br />5 A
[Ie] rated operational current
1.5 A 120 V, AC-12 IEC 60947-5-1<br />1 A 240 V, AC-12 IEC 60947-5-1<br />1 A 24 V, DC-12 IEC 60947-5-1<br />0.7 A 24 V, DC-13 IEC 60947-5-1<br />0.2 A 125 V, DC-12 IEC 60947-5-1<br />0.15 A 125 V, DC-13 IEC 60947-5-1
Electrical durability
100000 cycles, AC, 0.7 A 220 V IEC 60947-5-1 appendix C
Signalling type
Steady
current consumption
10 mA
Service life
30000 h
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
14…131 °F (-10…55 °C)
IP degree of protection
IP65 IEC 60529
Standards
JIS C 4520<br />JIS C 852<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />UL 508<br />IEC 60947-1
Product Certifications
CCC<br />cURus
Vibration resistance
1 mm 10…55 Hz)IEC 60068-2-6
Shock resistance
10 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice