schneider XB7EV06BP

Selling Points

  • 1High-efficiency design for reduced energy consumption.
  • 2Compact and lightweight for easy installation in tight spaces.
  • 3Wide input voltage range for flexibility in various applications.
  • 4Built-in protection features for enhanced reliability and safety.
  • 5Compliant with international safety standards for industrial use.
Product Details
XB7EV06BP
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB7
Product or Component Type
Pilot light
Device short name
XB7
Mounting diameter
0.9 in (22 mm)
Sale per indivisible quantity
10
Shape of signaling unit head
Round
cap/operator or lens colour
Blue
Light source
LED
Bulb base
Integral LED
[Us] Rated Supply Voltage
24 V AC/DC 50/60 Hz
Device presentation
Monolithic product
Height
1.1 in (29 mm)
Width
1.1 in (29 mm)
Depth
2.1 in (54 mm)
Terminals description ISO n°1
(X1-X2)PL
Net Weight
0.04 lb(US) (0.02 kg)
Device mounting
Fixing hole 0.9 in (22.5 mm) 22.3 +0.4/0 EN/IEC 60947-5-1
Fixing center
>= 30 x 40 mm support panel) metal 0.04…0.2 in (1…6 mm)<br />>= 30 x 40 mm support panel) plastic 0.08…0.2 in (2…6 mm)
Fixing mode
Fixing nut beneath head 17.7…21.2 lbf.in (2…2.4 N.m)
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1<br />Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end EN/IEC 60947-1
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw head
Cross JIS No 1<br />Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
[Ui] rated insulation voltage
250 V 3)EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV EN/IEC 60947-1
Signalling type
Steady
Supply voltage limits
19.2…30 V DC<br />21.6…26.4 V AC
current consumption
20...27 mA
Service life
70000 h at rated voltage and 25 °C
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Overvoltage category
Class II IEC 60536
IP degree of protection
IP20 IEC 60529 rear face)<br />IP65 IEC 60529 front face)
NEMA degree of protection
NEMA 4 UL 50 E<br />NEMA 12 UL 50 E
Standards
EN/IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C8201-5-1<br />EN/IEC 60947-1<br />UL 508<br />JIS C8201-1
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Electromagnetic compatibility
Disturbing field emission class B conforming to EN 55011

Specifications may be subject to change without notice