schneider XB7ND21

Selling Points

  • 1Monolithic design for easy installation - Eliminates the need for components, making it quick to install.
  • 2Flexible wiring solution - 4-terminals with 2-contacts offer increased wiring flexibility.
  • 3Impact, dust, and water resistant - Ideal for operation in harsh environments due to its IP65 rating.
  • 4Wide operating temperature range - Operates from -25°C to 70°C, ensuring versatility in usage.
  • 5Durable construction with plastic bezel - Provides good resistance to chemical agents and electrical insulation.
Product Details
XB7ND21
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB7
Product or Component Type
Selector switch
Device short name
XB7
Mounting diameter
0.9 in (22 mm)
Sale per indivisible quantity
10
Net Weight
0.057 lb(US) (0.026 kg)
IP degree of protection
IP20 IEC 60529 rear face)<br />IP65 IEC 60529 front face)
Shape of signaling unit head
Round
Type of operator
stay put
Operator profile
Black standard handle
Operator position information
2 positions 90°
Contacts type and composition
1 NO
Positive opening
Without
CAD overall width
1.1 in (29 mm)
CAD overall height
1.1 in (29 mm)
CAD overall depth
2.7 in (68.5 mm)
Terminals description ISO n°1
(13-14)NO
Device mounting
Fixing hole 0.9 in (22.5 mm) 22.3 +0.4/0 IEC 60947-1
Fixing center
>= 30 x 40 mm support panel) metal 0.04…0.2 in (1…6 mm)<br />>= 30 x 40 mm support panel) plastic 0.08…0.2 in (2…6 mm)
Fixing mode
Fixing nut 17.7…21.2 lbf.in (2…2.4 N.m)
Contact operation
Slow-break
Mechanical durability
300000 cycles
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1<br />Screw clamp terminals, 1 x 0.34...2 x 2.5 mm² without cable end IEC 60947-1
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) IEC 60947-1
Shape of screw head
Cross JIS No 1<br />Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Short-circuit protection
4 A cartridge fuse gG IEC 60947-5-1
[Ui] rated insulation voltage
250 V 3)IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV IEC 60947-1
[Ie] rated operational current
0.1 A 250 V, DC-13, R300 IEC 60947-5-1<br />0.22 A 125 V, DC-13, R300 IEC 60947-5-1<br />0.3 A 240 V, AC-14, D300 IEC 60947-5-1<br />0.6 A 120 V, AC-14, D300 IEC 60947-5-1
Electrical durability
1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C
Electrical reliability
Λ < 10exp(-6) 17 V 5 mA IEC 60947-5-4
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Electrical shock protection class
Class II IEC 61140
NEMA degree of protection
NEMA 12 UL 50 E<br />NEMA 3 UL 50 E
Standards
CSA C22.2 No 14<br />UL 508<br />IEC 60947-5-1<br />JIS C8201-5-1<br />IEC 60947-1<br />JIS C8201-1
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
50 gn 11 ms) half sine wave acceleration IEC 60068-2-27<br />30 gn 18 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice