Product Model

GRTE18-N2442V

In Stock
Last updated: 2025/5/1
sick GRTE18-N2442V

Selling Points

  • 1Detects objects from 5 mm to 550 mm with precision.
  • 2Designed for use in harsh environments with chemical resistance.
  • 3Ensures reliable detection with minimal false triggers.
  • 4Potentiometer adjustment for optimal light spot size (Ø 9 mm at 400 mm).
  • 5Complementary switching mode for easy integration into control systems.
Product Details
GRTE18-N2442V
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Functional principle
Photoelectric proximity sensor
Functional principle detail
Energetic
Dimensions (W x H x D)
18 mm x 18 mm x 73.5 mm
Housing design (light emission)
Cylindrical
Housing length
73.5 mm
Thread length
49.3 mm
Thread diameter (housing)
M18 x 1
Optical axis
Axial
Sensing range max.
5 mm ... 550 mm
Sensing range
10 mm ... 400 mm
Type of light
Visible red light
Light source
PinPoint LED
Light spot size (distance)
Ø 9 mm (400 mm)
Wave length
650 nm
Adjustment
Potentiometer, 270°
Indication_LED green
Operating indicatorStatic on: power on
Indication_LED yellow
Status of received light beamStatic on: object presentStatic off: object not present
Special applications
Hygienic and washdown zones
Supply voltage UB
10 V DC ... 30 V DC
Ripple
< 5 V
Current consumption
30 mA
Switching output
NPN
Output function
Complementary
Switching mode
Light/dark switching
Signal voltage NPN HIGH/LOW
Approx. V#!#/ ≤ 3 V
Output current Imax.
≤ 100 mA
Response time
< 1,000 µs
Switching frequency
500 Hz
Connection type
Male connector M12, 4-pin
Circuit protection
A7)#!#B8)#!#D9)
Protection class
III
Weight
65 g
Housing material
Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material
Plastic, PMMA
Tightening torque, max.
90 Nm
Enclosure rating
IP67#!#IP6810)#!#IP69K11)
Items supplied
Fastening nuts (2 x)
Electromagnetic compatibility (EMC)
EN 60947-5-2
Ambient operating temperature
–25 °C ... +55 °C
Ambient temperature, storage
–30 °C ... +75 °C
UL File No.
E348498