Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
4
Total number of potentials
2
Number of levels
2
Width
5.2?mm?/ 0.205?inches
Height
69.7?mm?/ 2.744?inches
Depth from upper-edge of DIN-rail
51.7?mm?/ 2.035?inches
Mounting type
DIN-35 rail
Marking level
Center/side marking
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.238MJ
Weight
10.6g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-27
eCl@ss 9.0
27-14-11-27
ETIM 9.0
EC000903
ETIM 8.0
EC000903
ECCN
NO US CLASSIFICATION
PU (SPU)
50?pcs
Packaging type
box
Country of origin
DE
GTIN
4045454375614
Customs tariff number
8536904000
CAS-No.
7439-92-1
REACH Candidate List Substance
2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
7(a)
SCIP notification number (Austria)
91a7e30e-7af7-46ba-94f4-b54e180c2fcb
SCIP notification number (Belgium)
fe1247ab-fe0c-491c-829a-e4a284050576
SCIP notification number (Bulgaria)
f5d90077-1205-4d07-8193-c4c3970e69ba
SCIP notification number (Czech Republic)
d78c3fbb-a6b3-44e2-ae50-f01c84130a18
SCIP notification number (Denmark)
a1d6b56d-045d-4c4c-b333-142113699734
SCIP notification number (Finland)
992dbfc1-325b-4a95-96ce-eaf0d1ab8cd2
SCIP notification number (France)
d2b1ce8b-c733-450d-b99f-f6691ee57603
SCIP notification number (Germany)
4e63454f-ab20-4532-8a77-92c03d581d0b
SCIP notification number (Hungary)
1905f969-0d46-434a-afef-47cb0b9ab4b0
SCIP notification number (Italy)
f07b8d3e-867e-4435-aa5c-6cfb118f2f19
SCIP notification number (Netherlands)
4cf153a0-885d-4c1f-ad49-ede760d528af
SCIP notification number (Poland)
9eefcc16-2dcd-481b-bccb-13de84bc80c9
SCIP notification number (Romania)
e8839130-4918-47ac-a845-62a63aed6a62
SCIP notification number (Sweden)
9f9e9aff-ca78-423d-abfa-f2cf7bb5eeda
Ratings per
IEC/EN 60947-7-1
Rated current
0.5A
Nominal voltage
250V
Reverse voltage
1,000V
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
2.5 mm2
Solid conductor
0.25 … 4?mm2?/ 22 … 12?AWG
Solid conductor; push-in termination
0.75 … 4?mm2?/ 18 … 12?AWG
Fine-stranded conductor
0.25 … 4?mm2?/ 22 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5?mm2?/ 22 … 14?AWG
Fine-stranded conductor; with ferrule; push-in termination
1 … 2.5?mm2?/ 18 … 14?AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
10 … 12?mm?/ 0.39 … 0.47?inches
Wiring direction
Front-entry wiring
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed