wago 2010-1203

Selling Points

  • 1DIN Rail Mounting: Designed for easy installation on DIN rail 35 x 15 and 35 x 7.5.
  • 2Push-in CAGE CLAMP: Fast and secure wire termination with push-in technology.
  • 3Ex e II Compliance: Suitable for hazardous environments with Ex e II certification.
  • 4Side and Center Marking: Clear identification of terminals for easy wiring.
  • 510 mm² Conductor Area: Supports conductors up to 10 mm² for robust connections.
Product Details
2010-1203
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
2
Total number of potentials
1
Number of levels
1
Number of jumper slots
2
Width
10 mm / 0.394 inches
Height
67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail
36.9 mm / 1.453 inches
Depth
43.5 mm / 1.713 inches
Mounting type
DIN-35 rail
Marking level
Center/side marking
Note (material data)
Information on material specifications can be found here
Color
red
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.329MJ
Weight
17.3g
Processing temperature
-35 … +85 °C
Continuous operating temperature
-60 … +105 °C
Product Group
22 (TOPJOB S)
ECCN
NO US CLASSIFICATION
PU (SPU)
25 pcs
Packaging type
Box
Country of origin
DE
GTIN
4045454290696
Customs tariff number
85369010000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
ATEX: PTB 05 ATEX 1070 U / IECEx: PTB 06.0003U (Ex eb IIC Gb)
Rated voltage (III / 3)
800V
Rated impulse voltage (III / 3)
8kV
Rated current
57A
Current at conductor cross-section (max.) mm2
76A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
65A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
65A
Rated voltage CSA (Use Group B)
600V
Rated current CSA (Use Group B)
65A
Rated voltage CSA (Use Group C)
600V
Rated current CSA (Use Group C)
65A
Reference hazardous areas
See application instructions in section “Knowledge andDownloads – Documentation – Additional Information: Technical Section; Technical Explications”
Rated voltage EN (Ex e II)
550V
Rated current (Ex e II)
51A
Power loss, per pole (potential)
1.819W
Rated current I<sub>N</sub> for specified power loss
57A
Resistance value for specified, current-dependent power loss
0.001Ω
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
10 mm2
Solid conductor
0.5 … 16 mm2 / 20 … 6 AWG
Solid conductor; push-in termination
4 … 16 mm2 / 14 … 6 AWG
Fine-stranded conductor
0.5 … 16 mm2 / 20 … 6 AWG
Fine-stranded conductor; with insulated ferrule
0.5 … 10 mm2 / 20 … 8 AWG
Fine-stranded conductor; with ferrule; push-in termination
4 … 10 mm2 / 12 … 8 AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.AWG specifications were converted according to IEC.
Strip length
17 … 19 mm / 0.67 … 0.75 inches
Wiring direction
Front-entry wiring

Specifications may be subject to change without notice