Product Model

2202-1311/1000-411

In Stock
Last updated: 2025/5/1
wago 2202-1311/1000-411

Selling Points

  • 1Made from high-quality polyamide (PA66) for excellent insulation and durability.
  • 2Features push-in CAGE CLAMP technology for quick and tool-free conductor connection.
  • 3Designed for DIN-rail 35 x 15 and 35 x 7.5, ensuring versatile mounting options.
  • 4Rated for 0.5 A, making it suitable for various electrical applications.
  • 5Equipped with a 1N4007 diode for reliable protection against voltage spikes.
Product Details
2202-1311/1000-411
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
3
Total number of potentials
1
Number of levels
1
Number of jumper slots
1
Width
5.2 mm / 0.205 inches
Height
59.2 mm / 2.33 inches
Depth from upper-edge of DIN-rail
32.9 mm / 1.295 inches
Mounting type
DIN-35 rail
Marking level
Center/side marking
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.175MJ
Weight
7.9g
Processing temperature
-35 … +85 °C
Continuous operating temperature
-60 … +105 °C
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
Box
Country of origin
DE
GTIN
4066966324365
Customs tariff number
85369010000
CAS-No.
7439-92-1
REACH Candidate List Substance
2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
7(a)
SCIP notification number (Austria)
52bbdf8d-491c-4335-ae66-9a23dfc3b192
SCIP notification number (Belgium)
41f43c12-bc9d-4814-8b81-b0fb62340ea7
SCIP notification number (Czech Republic)
0954dac7-24c1-47b5-992b-1903155d731d
SCIP notification number (Denmark)
26658a57-77eb-491c-9c77-e40f1a1d5f43
SCIP notification number (Finland)
dc9a1531-9b18-4304-8792-d807115d4b25
SCIP notification number (Germany)
7a0f3cab-2fb2-4ca5-8691-b648ac46ecb5
SCIP notification number (Netherlands)
63f2ed46-ac92-44b5-bf92-74a85b7f9a71
SCIP notification number (Poland)
8b297668-adcc-435a-9d8a-1ca2e0e888bf
SCIP notification number (Romania)
ffd462ca-0a4f-4b69-87b9-002ccc007df6
SCIP notification number (Sweden)
f061c383-1f07-4926-8233-f2b07e3a1844
Nominal voltage
250V
Reverse voltage
1,000V
Continuous current (max.)
500 mA
Connection technology
Push-in CAGE CLAMP?
Actuation type
Push-button
Connectable conductor materials
Copper
Nominal cross-section
2.5 mm2
Solid conductor
0.25 … 4 mm2 / 22 … 12 AWG
Solid conductor; push-in termination
0.75 … 4 mm2 / 18 … 12 AWG
Fine-stranded conductor
0.25 … 4 mm2 / 22 … 12 AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5 mm2 / 22 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination
1 … 2.5 mm2 / 18 … 14 AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
10 … 12 mm / 0.39 … 0.47 inches
Wiring direction
Front-entry wiring
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed