wago 2252-1202

Selling Points

  • 1Designed for Ex e II applications with a single deck and side/center marking slots.
  • 2Accommodates one feed-through pole with two wires (one push-in each) up to 2.5mm².
  • 3Supports wire sizes from 0.25mm² to 4mm² or #22AWG to #12AWG.
  • 4Rated for a current of 24A with push-in CAGE CLAMP spring connections.
  • 5Mounts on a DIN-15 rail with a width of 5.2mm for compact installation.
Product Details
2252-1202
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
2
Total number of potentials
1
Number of levels
1
Number of jumper slots
1
Width
5.2?mm?/ 0.205?inches
Height
36.5?mm?/ 1.437?inches
Depth from upper-edge of DIN-rail
30.8?mm?/ 1.213?inches
Mounting type
DIN-15 rail
Marking level
Center/side marking
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.103MJ
Weight
4.2g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
ETIM 9.0
EC000897
ETIM 8.0
EC000897
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
Box
Country of origin
IN
GTIN
4066966310764
Customs tariff number
85369010000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
ATEX: PTB 20 ATEX 1013 U / IECEx: PTB 20.0029U (Ex eb IIC Gb)
Rated voltage (III / 3)
800V
Rated impulse voltage (III / 3)
8kV
Rated current
24A
Current at conductor cross-section (max.) mm2
32A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
20A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
20A
Rated voltage CSA (Use Group B)
600V
Rated current CSA (Use Group B)
20A
Rated voltage CSA (Use Group C)
600V
Rated current CSA (Use Group C)
20A
Reference hazardous areas
See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Rated voltage EN (Ex e II)
550V
Rated current (Ex e II)
22A
Rated current (Ex e II) with jumper
20A
Power loss, per pole (potential)
0.766W
Rated current I<sub>N</sub> for specified power loss
24A
Resistance value for specified, current-dependent power loss
0.001Ω
Connection technology
Push-in CAGE CLAMP?
Actuation type
Push-button
Connectable conductor materials
Copper
Nominal cross-section
2.5 mm2
Solid conductor
0.25 … 4?mm2?/ 22 … 12?AWG
Solid conductor; push-in termination
1 … 4?mm2?/ 18 … 12?AWG
Fine-stranded conductor
0.25 … 4?mm2?/ 22 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5?mm2?/ 22 … 14?AWG
Fine-stranded conductor; with ferrule; push-in termination
1 … 2.5?mm2?/ 18 … 14?AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
10 … 12?mm?/ 0.39 … 0.47?inches
Wiring direction
Front-entry wiring

Specifications may be subject to change without notice