Product Model

231-532/108-000

In Stock
Last updated: 2025/4/29
wago 231-532/108-000

Selling Points

  • 1Highly Reliable Connection: Ensures secure and maintenance-free connections in demanding environments.
  • 2Easy Installation: Designed for quick and straightforward installation on PCBs.
  • 3Robust Construction: Built with robust materials for long-lasting performance.
  • 4Anti-Rotation Protection: Prevents accidental disconnection with anti-rotation protection.
  • 5Compliant with Safety Standards: Meets CSA and UL 1059 approvals for added safety assurance.
Product Details
231-532/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
2
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
20.16?mm?/ 0.794?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1 x 1?mm
Drilled hole diameter with tolerance
1.4(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.026MJ
Weight
1.5g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
200?pcs
Packaging type
box
Country of origin
PL
GTIN
4044918866798
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
09c01796-e9df-4150-9093-65279eb7a6cd
SCIP notification number (Belgium)
73d09bba-7591-4ea9-903f-c93d119b1586
SCIP notification number (Bulgaria)
3c4c1f5a-76c5-4923-80cb-79f91c68d136
SCIP notification number (Czech Republic)
b5a79117-209d-404b-849b-ce3000cca35d
SCIP notification number (Denmark)
e14c8b1b-f776-4424-a91b-59fa8ca094b5
SCIP notification number (Finland)
ebf0e28f-0284-4606-aa69-9935d6a9b60d
SCIP notification number (France)
114d2e17-28f0-44c0-aa2b-4c955cd11cc1
SCIP notification number (Germany)
200aa965-24a6-4fc6-a85c-7ca480c0511d
SCIP notification number (Hungary)
20b9a933-11f8-43ad-b799-116ca8a850a0
SCIP notification number (Italy)
e328d323-ca0a-42b9-98bd-f1ce5e01af8a
SCIP notification number (Netherlands)
ade09e6d-dc01-4fea-a62d-5fd0c0ceffc9
SCIP notification number (Poland)
eee8fdc9-68fd-4ab6-a1b7-a1898007126d
SCIP notification number (Romania)
97ee6199-8e2e-40ba-9047-7bc473aa7611
SCIP notification number (Sweden)
1783d6a7-fc54-4498-8aa6-2739c4ddbc61
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
320V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
12A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
2
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice