Product Model
231-532/108-000

Selling Points
- 1Highly Reliable Connection: Ensures secure and maintenance-free connections in demanding environments.
- 2Easy Installation: Designed for quick and straightforward installation on PCBs.
- 3Robust Construction: Built with robust materials for long-lasting performance.
- 4Anti-Rotation Protection: Prevents accidental disconnection with anti-rotation protection.
- 5Compliant with Safety Standards: Meets CSA and UL 1059 approvals for added safety assurance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 2 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 20.16?mm?/ 0.794?inches | Height | 12.2?mm?/ 0.48?inches |
Height from the surface | 8.4?mm?/ 0.331?inches | Depth | 12?mm?/ 0.472?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.026MJ |
Weight | 1.5g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 200?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4044918866798 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 09c01796-e9df-4150-9093-65279eb7a6cd | SCIP notification number (Belgium) | 73d09bba-7591-4ea9-903f-c93d119b1586 |
SCIP notification number (Bulgaria) | 3c4c1f5a-76c5-4923-80cb-79f91c68d136 | SCIP notification number (Czech Republic) | b5a79117-209d-404b-849b-ce3000cca35d |
SCIP notification number (Denmark) | e14c8b1b-f776-4424-a91b-59fa8ca094b5 | SCIP notification number (Finland) | ebf0e28f-0284-4606-aa69-9935d6a9b60d |
SCIP notification number (France) | 114d2e17-28f0-44c0-aa2b-4c955cd11cc1 | SCIP notification number (Germany) | 200aa965-24a6-4fc6-a85c-7ca480c0511d |
SCIP notification number (Hungary) | 20b9a933-11f8-43ad-b799-116ca8a850a0 | SCIP notification number (Italy) | e328d323-ca0a-42b9-98bd-f1ce5e01af8a |
SCIP notification number (Netherlands) | ade09e6d-dc01-4fea-a62d-5fd0c0ceffc9 | SCIP notification number (Poland) | eee8fdc9-68fd-4ab6-a1b7-a1898007126d |
SCIP notification number (Romania) | 97ee6199-8e2e-40ba-9047-7bc473aa7611 | SCIP notification number (Sweden) | 1783d6a7-fc54-4498-8aa6-2739c4ddbc61 |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 2 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice