Product Model
231-533/108-000

Selling Points
- 1Horizontal or Vertical PCB Mounting: Mount headers in any orientation with straight or angled solder pins.
- 2Threaded Flange: Secure connection with a threaded flange for added stability.
- 35.08 mm Pin Spacing: Standard pin spacing for easy integration into various electronic systems.
- 4Coding Fingers: Includes coding fingers for easy identification and organization.
- 5Gold-Plated Contacts: Gold-plated or partially gold-plated contact surfaces for enhanced durability and conductivity.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 3 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 25.24?mm?/ 0.994?inches | Height | 12.2?mm?/ 0.48?inches |
Height from the surface | 8.4?mm?/ 0.331?inches | Depth | 12?mm?/ 0.472?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.032MJ |
Weight | 1.8g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 200?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4044918866828 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 08dfd299-c06f-4b8c-9721-f226736d8289 | SCIP notification number (Belgium) | df2543b0-234d-49dd-a856-36f39a376eb7 |
SCIP notification number (Bulgaria) | c465cb03-3b41-489c-aecb-044f127215df | SCIP notification number (Czech Republic) | c6fb789c-0e54-4b84-8a84-d8b339baed2a |
SCIP notification number (Denmark) | 8f1328c8-eff9-461e-a004-a15714ccafae | SCIP notification number (Finland) | a990c0cd-37cc-49f5-8875-8987e5ef9b44 |
SCIP notification number (France) | 011e785f-c7d5-4888-aef2-d3631260e303 | SCIP notification number (Germany) | b91735df-6c9a-451d-8683-110942a69193 |
SCIP notification number (Hungary) | 39ecd190-f626-46e5-b788-95cb20663207 | SCIP notification number (Italy) | 8a8d9d61-7347-4eff-a800-2d837f08fdf9 |
SCIP notification number (Netherlands) | 7d601439-c5c3-40f0-ab40-8f1167b04fd9 | SCIP notification number (Poland) | 6809eb9d-280b-4fad-82b9-1d0cbc2d8707 |
SCIP notification number (Romania) | 0d9c7c21-9a94-41ef-9088-d2acfdec944a | SCIP notification number (Sweden) | e9162e91-7133-4778-9714-8b76ba23e36c |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 3 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice