Product Model
231-564/108-000

Selling Points
- 1High-Current Capability: Supports up to 16 A nominal current.
- 2Angled Design: Easy to mount on PCBs with angled solder pins.
- 3Threaded Flange: Secure and stable connection with a threaded flange.
- 4Ratings Compliance: Meets IEC/EN 60664-1 and UL 1059 standards.
- 5Durable Construction: Made from high-quality materials like polyamide 66 (PA 66) and electrolytic copper (Ecu).
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 4 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 30.32?mm?/ 1.194?inches | Height | 12.2?mm?/ 0.48?inches |
Height from the surface | 8.4?mm?/ 0.331?inches | Depth | 12?mm?/ 0.472?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1.2 x 1.2?mm |
Drilled hole diameter with tolerance | 1.7(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.037MJ |
Weight | 2.3g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | DE |
GTIN | 4045454843731 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 65887fcd-74d8-4230-9514-439fc93b7457 | SCIP notification number (Belgium) | f9d4dcfd-0d87-402a-b545-fe6ba7a6bdcf |
SCIP notification number (Bulgaria) | b55bca63-2db3-47e0-916b-5536523f90c5 | SCIP notification number (Czech Republic) | 08b9c036-6b63-4209-8489-1e14d0e4b379 |
SCIP notification number (Denmark) | 80025ce4-a96f-44ac-8b18-3167b685098f | SCIP notification number (Finland) | efb85f3c-7ebc-4d17-a5a0-867cecd5fe26 |
SCIP notification number (France) | 34d526cf-860f-4904-b5ea-980b7b831962 | SCIP notification number (Germany) | edbd42ae-6d0b-4823-9b00-e985eee318fa |
SCIP notification number (Hungary) | a5c0c3a8-f7e8-4af1-a233-adb56bbc8e70 | SCIP notification number (Italy) | 197ffd89-7bec-4442-942b-c6c96bfa4bc3 |
SCIP notification number (Netherlands) | c78ca40f-fc97-460c-a9e6-6c369f675d8f | SCIP notification number (Poland) | 60d131a4-3336-4489-bdc1-4999d636e58e |
SCIP notification number (Romania) | 715f48b5-a6f6-4b60-a1ef-5a3258991a30 | SCIP notification number (Sweden) | 7de73825-d34c-4060-a6fa-dfc347fb00fe |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 250V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 16A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 4 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice