Product Model

231-566/108-000

In Stock
Last updated: 2025/5/3
wago 231-566/108-000

Selling Points

  • 1Ideal for multiple connections in electronic circuits.
  • 2Facilitates easy PCB mounting and reduces strain on solder joints.
  • 3Supports nominal currents up to 16 A per pin.
  • 4Provides secure mounting options for various applications.
  • 5Measures 1.2 x 1.2 mm, perfect for space-constrained projects.
Product Details
231-566/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
6
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
40.48?mm?/ 1.594?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1.2 x 1.2?mm
Drilled hole diameter with tolerance
1.7(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.048MJ
Weight
3.1g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454843755
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
e627aac2-b6c8-414b-969e-439af77e41c5
SCIP notification number (Belgium)
cf371029-cdd3-4e6b-b4ab-3d4ed9c455c5
SCIP notification number (Bulgaria)
bf00419b-f9bf-40e5-bfdc-e551a2435356
SCIP notification number (Czech Republic)
25882764-6b93-43a4-95aa-749dddd5010b
SCIP notification number (Denmark)
982f2999-779a-4122-9d64-876f23b752a3
SCIP notification number (Finland)
e5d7a98d-f39e-46ad-b1c0-2bc51e4348e6
SCIP notification number (France)
14aebc56-12bf-495a-a120-12a290eeba0b
SCIP notification number (Germany)
7e82a831-5894-44e1-a380-7687ac473e20
SCIP notification number (Hungary)
9259217b-4920-42d8-a34f-c0485b955a83
SCIP notification number (Italy)
0f6be4d6-679b-4076-b36f-5f9d46aabf2c
SCIP notification number (Netherlands)
766cd2d5-4d25-4bc9-9311-10b888ca86e9
SCIP notification number (Poland)
5656da35-25fe-40f7-8efa-6487eacae7d8
SCIP notification number (Romania)
09d3623e-3dc8-4d38-874c-04d00e306f2b
SCIP notification number (Sweden)
dc7ad98d-1838-4285-95a8-2bac3b2c3187
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
6
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice