Product Model

257-416

In Stock
Last updated: 2025/4/29
wago 257-416

Selling Points

  • 1Programmable Fieldbus Controller: Control digital and analog signals with ease.
  • 2Ethernet TCP/IP Connectivity: Supports 10/100 Mbps Ethernet for seamless communication.
  • 3Versatile Signal Handling: Handles both digital and analog signals in one device.
  • 4Compact Design: Compact size for easy integration into industrial settings.
  • 5High Reliability: Built for reliability in demanding industrial environments.
Product Details
257-416
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
16
Total number of potentials
16
Number of connection types
1
Number of levels
1
Pin spacing
5/5.08?mm?/ 0.197/0.2?inches
Width
82.9?mm?/ 3.264?inches
Height
24.4?mm?/ 0.961?inches
Height from the surface
20.4?mm?/ 0.803?inches
Depth
14.2?mm?/ 0.559?inches
Solder pin length
4mm
Solder pin dimensions
0.7 x 0.7?mm
Drilled hole diameter with tolerance
1.1(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (in-line)
Number of solder pins per potential
2
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.309MJ
Weight
18.3g
Limit temperature range
-60 … +105?°C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
60?(15)?pcs
Packaging type
box
Country of origin
PL
GTIN
4044918411875
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
24A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Push-button
Solid conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1.5?mm2
Note (conductor cross-section)
12 AWG: THHN, THWN
Strip length
5 … 6?mm?/ 0.2 … 0.24?inches
Conductor connection direction to PCB
Number of poles
16

Specifications may be subject to change without notice