Product Model
713-1407/116-000/997-407

Selling Points
- 1100% protected against mismating for secure connections.
- 20.8 x 0.8 mm solder pins for precise assembly.
- 3Straight design with levers for easy handling.
- 4Available in tape-and-reel packaging for efficient use.
- 5Meets CSA and UL 1059 approvals for reliability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 14 | Number of connection types | 1 |
Number of levels | 2 | Pin spacing | 3.5?mm?/ 0.138?inches |
Width | 32.6?mm?/ 1.283?inches | Height | 15.9?mm?/ 0.626?inches |
Height from the surface | 13.5?mm?/ 0.531?inches | Depth | 13.3?mm?/ 0.524?inches |
Solder pin length | 2.4mm | Solder pin dimensions | 0.8 x 0.8?mm |
Plated through-hole diameter (THR) | 1.3(+0.1)mm | Reel diameter of tape-and-reel packaging | 330mm |
Tape width | 56mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | Yes |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Locking lever | PCB contact | THR |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | black |
Material group | I | Insulation material (main housing) | Polyphthalamide (PPA GF) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Weight | 3.8g |
MSL per J-STD 020D | 1 | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | eCl@ss 10.0 | 27-44-04-02 |
eCl@ss 9.0 | 27-44-04-02 | ETIM 9.0 | EC002637 |
ETIM 8.0 | EC002637 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 120?pcs | Packaging type | bag |
Country of origin | DE | GTIN | 4050821308751 |
Customs tariff number | 8536694040 | RoHS Compliance Status | Compliant,No Exemption |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 80V |
Rated impulse voltage (III / 3) | 2.5kV | Rated voltage (III/2) | 160V |
Rated surge voltage (III/2) | 2.5kV | Nominal voltage (II/2) | 250V |
Rated surge voltage (II/2) | 2.5kV | Rated current | 10A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 150V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group C) | 50V | Rated current UL (Use Group C) | 10A |
Rated voltage CSA (Use Group B) | 150V | Rated current CSA (Use Group B) | 12A |
Number of poles | 14 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice