Product Model
734-144/108-000

Selling Points
- 1100% protected against mismating for secure connections.
- 214-pole configuration with 3.5 mm pin spacing.
- 3Straight solder pins with 1.0 x 1.0 mm diameter.
- 4Light gray color with threaded flange for easy mounting.
- 5Compliant with IEC/EN 60664-1 and UL 1977 standards.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 14 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 3.5?mm?/ 0.138?inches |
Width | 58.5?mm?/ 2.303?inches | Height | 12.3?mm?/ 0.484?inches |
Height from the surface | 8.5?mm?/ 0.335?inches | Depth | 8.5?mm?/ 0.335?inches |
Solder pin length | 4.5mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | Yes |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | light gray |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.061MJ |
Weight | 3.8g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454618704 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 1a0c55c1-4625-431e-97a3-dbe2c099d222 | SCIP notification number (Belgium) | b8a4b078-f9cd-4e18-a57e-1d0c9ee4cacf |
SCIP notification number (Bulgaria) | fa91613e-4d21-4ec4-8688-91a12f7874b1 | SCIP notification number (Czech Republic) | b7d65a6d-4829-4b77-a158-c084b49e1520 |
SCIP notification number (Denmark) | 675b906d-3e37-4353-9ef6-de71e4b40d67 | SCIP notification number (Finland) | 58d35f63-a1a3-4163-90e9-456c48960364 |
SCIP notification number (France) | 7ca72e17-99b9-458d-bbdd-84babbf54971 | SCIP notification number (Germany) | 8827f2df-933d-472d-bb53-dfe7d0410150 |
SCIP notification number (Hungary) | 8fab3213-0598-4589-b3b1-fb2a1bde2575 | SCIP notification number (Italy) | b0596f1e-cd9b-420d-a4ed-bbef35b02169 |
SCIP notification number (Netherlands) | 5f4eecdb-2f04-4ef6-a46c-03002786e70c | SCIP notification number (Poland) | b1b71ffc-b79b-4dc4-8688-8c7b99e77210 |
SCIP notification number (Romania) | 93fa1ea2-a32a-4023-ba37-3a114caf5801 | SCIP notification number (Sweden) | b427777d-5d22-47d3-9709-c61dfb8fb8e9 |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 160V |
Rated impulse voltage (III / 3) | 2.5kV | Rated voltage (III/2) | 160V |
Rated surge voltage (III/2) | 2.5kV | Nominal voltage (II/2) | 320V |
Rated surge voltage (II/2) | 2.5kV | Rated current | 10A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 14 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice